Mueller matrix polarimetry with 3D integral imaging

A Carnicer, S Bosch, B Javidi - Optics Express, 2019 - opg.optica.org
In this paper, we introduce the Mueller matrix imaging concepts for 3D Integral Imaging
Polarimetry. The Mueller matrix of a complex scene is measured and estimated with 3D …

Towards compact and snapshot channeled Mueller matrix imaging

A Zaidi, S McEldowney, YH Lee, Q Chao, L Lu - Optics Letters, 2022 - opg.optica.org
A polarization transformation can be fully described by a 4?×? 4 matrix, known as the
Mueller matrix. To fully image an object's polarization response, one needs to compute the …

Mueller Matrix Imaging

O Arteaga, S Bian - Optical Polarimetric Modalities for Biomedical …, 2023 - Springer
Polarimetric imaging is a technique of great interest to study fiber-like macromolecules
present in biological tissues. As they exhibit a certain degree of anisotropy, it can be used as …

[引用][C] 主动偏振成像的系统结构概述

王霞, 张明阳, 陈振跃, 拜晓锋, 金伟其 - 红外与激光工程, 2013

Polarimetric images of a cone

PY Gerligand, MH Smith, RA Chipman - Optics express, 1999 - opg.optica.org
Scenes from a Mueller matrix movie of a brass cone are shown. From the Mueller matrix
image, a variety of polarization measures are calculated and displayed. These polarization …

Disentangling optical effects in 3D spiral-like, chiral plasmonic assemblies templated by a dark conglomerate liquid crystal

D Szepke, M Zarzeczny, M Pawlak, P Jarmuła… - The Journal of …, 2024 - pubs.aip.org
Chiral thin films showing electronic and plasmonic circular dichroism (CD) are intensively
explored for optoelectronic applications. The most studied chiral organic films are the …

Polarimetry group theory analysis in biological tissue phantoms by Mueller coherency matrix

F Fanjul-Vélez, N Ortega-Quijano, JL Arce-Diego - Optics Communications, 2010 - Elsevier
The characterization of biological tissues by optical techniques provides several advantages
over other techniques. Optical techniques enable to perform high resolution and contrast …

Mueller matrix ellipsometer using dual continuously rotating anisotropic mirrors

A Ruder, B Wright, D Peev, R Feder, U Kilic… - Optics Letters, 2020 - opg.optica.org
We demonstrate calibration and operation of a single wavelength (660 nm) Mueller matrix
ellipsometer in normal transmission configuration using dual continuously rotating …

Considerations in polarimeter design

JS Tyo - … Analysis, Measurement, and Remote Sensing III, 2000 - spiedigitallibrary.org
The relationship between system condition and SNR in reconstructed Stokes parameter
images is investigated for rotating compensator, variable retardance, and rotating analyzer …

Polarization studies for backscattering of RBC suspensions based on Mueller matrix decomposition

X Wang, J Lai, Z Li - Optics Express, 2012 - opg.optica.org
Tissue polarimetry has demonstrated its great potential in biomedical field presently. In this
study, the polarization characteristics of red blood cell (RBC) suspensions in a back …