Photometry, radiometry and 'the candela': evolution in the classical and quantum world

JC Zwinkels, E Ikonen, NP Fox, G Ulm, ML Rastello - Metrologia, 2010 - iopscience.iop.org
The metrological fields of photometry and radiometry and their associated units are closely
linked through the current definition of the base unit of luminous intensity—the candela …

Recent advances and perspectives in photometry in the era of LED lighting

E Ikonen - Measurement Science and Technology, 2023 - iopscience.iop.org
Photometry contributes to our understanding how the world is perceived by the human
visual system, where a specific example is an early study of photographic plates. Nowadays …

[图书][B] Handbook of applied photometry

C DeCusatis - 1998 - Springer
Bringing together the contributions of eleven leading photometric experts, this practical
reference guide presents common design formulas, essential rules-of-thumb, worked-out …

Predictable quantum efficient detector: I. Photodiodes and predicted responsivity

M Sildoja, F Manoocheri, M Merimaa, E Ikonen… - Metrologia, 2013 - iopscience.iop.org
The design and construction of a predictable quantum efficient detector (PQED), suggested
to be capable of measuring optical power with a relative uncertainty of 1 ppm (ppm= parts …

Realization of the National Institute of Standards and Technology detector-based spectral irradiance scale

HW Yoon, CE Gibson, PY Barnes - Applied Optics, 2002 - opg.optica.org
A detector-based spectral irradiance scale has been realized at the National Institute of
Standards and Technology (NIST). Unlike the previous NIST spectral irradiance scales, the …

Precision blackbody sources for radiometric standards

VI Sapritsky, BB Khlevnoy, VB Khromchenko… - Applied Optics, 1997 - opg.optica.org
The precision blackbody sources developed at the All-Russian Institute for Optical and
Physical Measurements (Moscow, Russia) and their characteristics are analyzed. The …

Twin-photon techniques for photo-detector calibration

G Brida, M Genovese, M Gramegna - Laser Physics Letters, 2005 - iopscience.iop.org
Twin-photon techniques for photo-detector calibration Page 1 Laser Physics Letters Twin-photon
techniques for photo-detector calibration To cite this article: G Brida et al 2006 Laser Phys. Lett. 3 …

Radiometry with cryogenic radiometers and semiconductor photodiodes

NP Fox - Metrologia, 1995 - iopscience.iop.org
The paper reviews some of the advances in optical radiation measurements made over the
last twenty years, particularly through the use of cryogenic radiometers and solid-state …

New spectral radiance scale from 220 nm to 2500 nm

R Friedrich, J Fischer - Metrologia, 2000 - iopscience.iop.org
Abstract The Physikalisch-Technische Bundesanstalt (PTB) has developed a spectral
comparator facility for accurate spectral radiance measurements. As a primary standard …

Traceability in fluorometry—part I: physical standards

J Hollandt, RD Taubert, J Seidel, U Resch-Genger… - Journal of …, 2005 - Springer
The inter-instrument, inter-laboratory, and long-term comparability of fluorescence data
requires the correction of the measured emission and excitation spectra for the wavelength …