Centration axis in refractive surgery

SA Mosquera, S Verma, C McAlinden - Eye and Vision, 2015 - Springer
The human eye is an asymmetric optical system and the real cornea is not a rotationally
symmetrical volume. Each optical element in the eye has its own optical and neural axes …

First European results of a new refractive lenticular extraction procedure—SmartSight by SCHWIND eye-tech-solutions

I Gabric, M Bohac, K Gabric, S Arba Mosquera - Eye, 2023 - nature.com
Background To evaluate vision 3 months after SmartSight lenticule extraction treatments.
Design Case series. Methods This case series of patients were treated at Specialty Eye …

[HTML][HTML] Immediate and short term visual recovery after SmartSurfACE photorefractive keratectomy

DTC Lin, SP Holland, S Verma, J Hogden… - Journal of …, 2019 - Elsevier
Purpose To investigate immediate and short-term visual recovery in a large cohort of 2093
myopic eyes (with or without astigmatism) treated with SmartSurf ACE procedure, a …

Analytical optimization of the cutting efficiency for generic cavitation bubbles

S Arba-Mosquera, P Naubereit, S Sobutas… - Biomedical Optics …, 2021 - opg.optica.org
A theoretical method to determine the optimum laser parameters for maximizing the cutting
efficiency for different materials (in particular human cornea) is proposed. The model is …

Optimum laser beam characteristics for achieving smoother ablations in laser vision correction

S Verma, J Hesser… - … Ophthalmology & Visual …, 2017 - iovs.arvojournals.org
Purpose: Controversial opinions exist regarding optimum laser beam characteristics for
achieving smoother ablations in laser-based vision correction. The purpose of the study was …

Analysis of the change in peak corneal temperature during excimer laser ablation in porcine eyes

SA Mosquera, S Verma - Journal of Biomedical Optics, 2015 - spiedigitallibrary.org
The objective is to characterize the impact of different ablation parameters on the thermal
load during corneal refractive surgery by means of excimer laser ablation on porcine eyes …

Effect of laser beam truncation (pinhole),(ordered) dithering, and jitter on residual smoothness after poly (methyl methacrylate) ablations, using a close-to-Gaussian …

S Verma, J Hesser, S Arba-Mosquera - Advanced Optical …, 2021 - degruyter.com
Smoother surfaces after laser vision correction have been widely accepted as a factor for
improving visual recovery regardless of the used technique (PRK, LASIK, or even SMILE) …

Simple Estimate of the Impact of M2 and Strehl Ratio on the Effective Focusable Spot Size

S Arba-Mosquera, P Naubereit, S Sobutas - Optics, 2024 - mdpi.com
A simple method (first-order approximation) to determine the impact of M2 and the Strehl
Ratio on the effective focusable spot size avoiding complex propagations of the beam …

Thermal load during corneal excimer laser ablation: impact of different ablation parameters

S Taneri, S Arba-Mosquera, A Rost… - Journal of Refractive …, 2020 - journals.healio.com
PURPOSE: To characterize the impact of different ablation parameters on the change in
peak corneal temperature during corneal excimer laser ablation. METHODS: Forty-two …

Analysis of impact of humidity and temperature on excimer laser ablation of polyethylene terephthalate, polymethylmethacrylate, and porcine corneal tissue

S Verma, T Kehrer, J Hesser… - Lasers in Surgery and …, 2020 - Wiley Online Library
Background and Objectives To analyze the impact of humidity and temperature on excimer
laser ablation of polyethylene terephthalate (PET), polymethylmethacrylate (PMMA) and …