Harmonic analysis in frequency and time domain

A Medina, J Segundo-Ramirez… - … on power delivery, 2013 - ieeexplore.ieee.org
This paper presents a review with a concise description and analysis of the fundamentals,
characteristics, analytical details, merits, and drawbacks associated with existing methods in …

Fast network reconfiguration in harmonic polluted distribution network based on developed backward/forward sweep harmonic load flow

MA Amini, A Jalilian, MRP Behbahani - Electric Power Systems Research, 2019 - Elsevier
Power quality of distribution network is an emerging issue due to rapid increase in usage of
non-linear loads on the one hand and utilization of sensitive devices on the other hand …

Exploring prospective benefits of electric vehicles for optimal energy conditioning in distribution networks

S Pirouzi, J Aghaei, T Niknam, H Farahmand, M Korpås - Energy, 2018 - Elsevier
A potentially beneficial new opportunity is emerging around the exchange of energy
between electric vehicles and the electrical energy grid, particularly as more low-carbon …

Experimental validation of dual H-bridge current flow controllers for meshed HVdc grids

S Balasubramaniam, CE Ugalde-Loo… - … on Power Delivery, 2017 - ieeexplore.ieee.org
The current-carrying capability of dc lines is limited by their thermal and electric stress limits.
Thus, the line current must be maintained within the permissible operational region to …

Two alternative robust optimization models for flexible power management of electric vehicles in distribution networks

S Pirouzi, J Aghaei, T Niknam, M Shafie-Khah… - Energy, 2017 - Elsevier
This paper presents a robust optimization problem of the flexible bidirectional power
management of a smart distribution network and harmonic compensation of nonlinear loads …

New metric recommended for IEEE standard 1547 to limit harmonics injected into distorted grids

X Zong, PA Gray, PW Lehn - IEEE Transactions on Power …, 2015 - ieeexplore.ieee.org
IEEE Standard 1547 defines grid connection standards for distributed resources (DRs). This
standard sets requirements for harmonic performance, which are particularly relevant when …

Proactive operation of electric vehicles in harmonic polluted smart distribution networks

S Pirouzi, J Aghaei, T Niknam… - IET Generation …, 2018 - Wiley Online Library
This study proposes combined framework for proactive operation, ie bidirectional active and
reactive power management, of the smart distribution network as well as harmonic …

Biogeography based optimization strategy for UPQC PI tuning on full order adaptive observer based control

SJ Alam, SR Arya, RK Jana - IET Generation, Transmission & …, 2021 - Wiley Online Library
Adaptive full order observer based control algorithm for unified power quality conditioner is
presented. The full order adaptive observer based algorithm is capable of estimating …

Improving power quality of wind energy conversion system with unconventional power electronic interface

L Gidwani, H Tiwari, RC Bansal - International Journal of Electrical Power & …, 2013 - Elsevier
The increasing interest to utilize wind energy as a power source prompted more researches
to be dedicated to the unconventional integration of this power source into the current grid …

Least mean mixed norm square/fourth adaptive algorithm with optimized FOPID gains for voltage power quality mitigation

SR Arya, KD Mistry, P Kumar - IEEE Journal of Emerging and …, 2023 - ieeexplore.ieee.org
The conventional adaptive least mean square (LMS) algorithm employs mean square error
(mse) as a cost function based on second-order power error. This limits the extraction of …