Locating switched capacitor using wavelet transform and hybrid principal component analysis network

YY Hong, BY Chen - IEEE Transactions on Power Delivery, 2007 - ieeexplore.ieee.org
The transient caused by capacitor switching is one of the important power quality (PQ)
problems. In particular, switching on the capacitor may result in an overvoltage to a sensitive …

On-line disturbance classification using nearest neighbor rule

AM Gaouda, SH Kanoun, MMA Salama - Electric power systems research, 2001 - Elsevier
This paper presents an automated on-line disturbance classification technique for different
power quality problems. This technique is based on wavelet multi-resolution analysis and …

A classification scheme for ventricular arrhythmias using wavelets analysis

K Balasundaram, S Masse, K Nair… - Medical & biological …, 2013 - Springer
Identification and classification of ventricular arrhythmias such as rhythmic ventricular
tachycardia (VT) and disorganized ventricular fibrillation (VF) are vital tasks in guiding …

Detection and classification of power quality disturbances in noisy conditions

H Zhang, P Liu, OP Malik - IEE Proceedings-Generation, Transmission and …, 2003 - IET
An approach to detect, localise and classify various types of power quality disturbances in
noisy conditions is proposed. The approach is based on the statistical properties of white …

Localization and classification of power quality disturbances using maximal overlap discrete wavelet transform and data mining based classifiers

S Upadhyaya, S Mohanty - IFAC-PapersOnLine, 2016 - Elsevier
This paper has proposed the time-series based maximal overlap discrete wavelet transform
(MODWT) technique for detection and localization of different types of power quality (PQ) …

The most suitable mother wavelet for steady-state power system distorted waveforms

WG Morsi, ME El-Hawary - 2008 canadian conference on …, 2008 - ieeexplore.ieee.org
The proliferation of nonlinear load in the electric power system leads to steady-state
waveform harmonic distortion. Since harmonic distortion has harmful effects on the electric …

[引用][C] 小波变换电力系统工学应用综述

王晶, 束洪春, 陈学允 - 电网技术, 2003

A new morphology method for enhancing power quality monitoring system

S Ouyang, J Wang - International journal of Electrical power & Energy …, 2007 - Elsevier
By means of mathematical morphology (MM), power quality monitoring systems can detect
disturbances very soon. However, the signal under investigation is often corrupted by …

Wavelet-based detection, localization, quantification and classification of short duration power quality disturbances

C Xiangxun - 2002 IEEE Power Engineering Society Winter …, 2002 - ieeexplore.ieee.org
This paper introduces a wavelet-based method for detecting, localizing, quantifying and
classifying short duration power quality disturbances (SDPQDs). A difference signal is …

[引用][C] FFT 和小波变换在电力系统谐波测量中的应用

蒋剑波, 刘贤兴, 王德明 - 高电压技术, 2005