Reliability assessment of different HVDC transmission system configurations considering transmission lines capacity restrictions and the effect of load level

SP Ramezanzadeh, M Mirzaie, M Shahabi - International Journal of …, 2021 - Elsevier
The ongoing increasing demand for electrical energy and the reliable access to remote
renewable energy generation points such as off-shore wind power stations or solar power …

A new topological structure of Z-source DC circuit breaker

T Li, Y Li, N Liu - IEEE Transactions on Circuits and Systems II …, 2022 - ieeexplore.ieee.org
Aiming at the slow fault removal speed of traditional Z-source DC circuit breakers, this brief
proposes a new Z-source DC circuit breaker topology to improve the speed of DC fault …

Optimum selection of circuit breaker parameters based on analytical calculation of overcurrent and overvoltage in multiterminal HVDC grids

Y Song, J Sun, M Saeedifard, S Ji, L Zhu… - IEEE Transactions …, 2019 - ieeexplore.ieee.org
This paper proposes a time-domain method to calculate the fault response in multiterminal
dc (MTdc) grids and the performance of hybrid dc breakers. The proposed method, based on …

A method to calculate short-circuit faults in high-voltage DC grids

Y Guo, H Li, Y Liang, G Wang - IEEE Transactions on Power …, 2020 - ieeexplore.ieee.org
Accurate fault calculation is vital for the parameter design and protection research of high-
voltage DC (HVDC) grids. This paper proposes a general method to calculate short-circuit …

Performance analysis of three-phase hybrid fault current limiter with one commutation circuit

AM Hamada, SSM Ghoneim, SAM Abdelwahab… - International Journal of …, 2021 - Elsevier
This paper describes the development of a hybrid fault current limiter and interrupting device
(HCLID) suitable for low and medium voltage AC or DC industrial installations. By …

A Novel Air Core Current Limiter Reactor for Medium and Low Voltage Systems

OE Gouda, ZE Afifi, MI Awaad - Electric Power Systems Research, 2023 - Elsevier
In this article the development of air core current limiting reactor provided with controller is
proposed to be used in AC fault current limitation of low and medium voltages. It contains an …

Transient fault identification method for bipolar short‐circuit fault on MMC‐HVDC overhead lines based on hybrid HVDC breaker

B Li, C Li, B Li, W Wen, H Cui, J Su - High Voltage, 2021 - Wiley Online Library
A bipolar short‐circuit transient fault identification method for overhead transmission lines in
modular multi‐level converter‐based high voltage direct current (MMC‐HVDC) grid based …

[引用][C] 阻容式直流断路器及其在柔直系统中的应用

王渝红, 王媛, 曾琦, 刘程卓 - 高电压技术, 2019

[引用][C] 一种强制换流型混合式高压直流断路器方案

王辉, 马超, 郝全睿, 韩国庆 - 高电压技术, 2019

Optimum design of hybrid HVDC circuit breakers using a parallel genetic algorithm and a MATLAB‐EMTP environment

JA Corea‐Araujo, JA Martinez‐Velasco… - IET Generation …, 2017 - Wiley Online Library
The optimum design of power system components is becoming a relevant topic in power
system studies. Genetic algorithms (GAs) are considered as a proper approach for …