Providing a combined solution to reduce very fast transient overvoltages in gas insulated substations

SA Mostafavi, SS Mousavimajd - Electric Power Systems Research, 2024 - Elsevier
The use of gas-insulated substations in high voltage levels of power systems is expanding
due to its many advantages, such as the need for less space, resistance to environmental …

Research on VFTO simulation analysis of 1000 kV GIS test circuit considering dynamic arcing model

Y Zhang, X Chen, H Cui, J Si, Z He… - IEEE Transactions …, 2022 - ieeexplore.ieee.org
In the research process of very fast transient overvoltage (VFTO), the accuracy of the
switching arc model largely determines the calculation results of VFTO. How to more …

A new approach for decision support of the selection of construction technology of high-voltage substations based on AHP method

P Rozga, A Kraslawski, A Klarecki… - IEEE …, 2021 - ieeexplore.ieee.org
The process of building and modernizing the high voltage substations generate the
problems concerning the determination of the optimal technological solutions, which should …

Numerical simulation and analytical calculation of the GIS transient enclosure voltage interaction with grounding system

AA Razi-Kazemi - Electric Power Systems Research, 2021 - Elsevier
Gas-insulated substations (GISs) are widely used in power systems due to high reliability,
convenient maintenance, and small area occupation. Transient enclosure voltage (TEV) is a …

Research on radiated disturbance to secondary cable caused by disconnector switching operation

L Cheng, Z He, J Liu, Z Yang, X Chen, Y Zhang… - Energies, 2022 - mdpi.com
With the development of smart grids, the application of localized relay protection devices has
greatly reduced the distance between the secondary equipment and the primary equipment …

Design of remote operation and maintenance platform of substation DC system for field defect handling

W Li, X Wang, J Shi - IOP Conference Series: Earth and …, 2021 - iopscience.iop.org
The current remote operation and maintenance platform of substation DC system mainly
relies on manual use of each independent monitoring device to collect and transmit data for …

Research on conducted disturbance to secondary cable caused by disconnector switching operation

X Chen, Z He, Y Zhang, J Si, S Wang… - Frontiers in Energy …, 2022 - frontiersin.org
The disconnector switching operation in GIS not only generates very fast transient
overvoltage (VFTO) in primary equipment, but also couples to the secondary system, which …

Measurement of multipath transients in secondary cables near a 500 kV gas-insulated switchgear during operations

Z Liu, Y Cui, B Zhang, J He - IEEE Transactions on Power …, 2022 - ieeexplore.ieee.org
Operation of SF 6 gas-insulated switchgear (GIS) produces very fast transient overvoltage,
which may interfere with the secondary system through many paths. As more and more …

Mitigation of transient ground potential rise in gas insulated substations during very fast transient overvoltage

M Alexandru, L Czumbil, A Polycarpou, H Nouri… - Electric Power Systems …, 2022 - Elsevier
This paper is focused on the assessment and mitigation of the transient response of a Gas
Insulated Substation's (GIS) grounding grid to the fault due to voltage breakdown using the …

Development and Experimental Research of VFTO Measuring Sensor

Z Teng, J Zhao, Q Wang, H Lu, J Zhang - Sensors, 2022 - mdpi.com
Very fast transient overvoltage (VFTO) generated by an operating disconnector is one of the
main reasons for electromagnetic disturbance in gas-insulated switchgear (GIS) substations …