Safety, efficacy, and predictability of laser in situ keratomileusis to correct myopia or myopic astigmatism with a 750 Hz scanning-spot laser system

M Tomita, M Watabe, S Yukawa… - Journal of Cataract & …, 2014 - journals.lww.com
Safety, efficacy, and predictability of laser in situ kerato... : Journal of Cataract & Refractive
Surgery Safety, efficacy, and predictability of laser in situ keratomileusis to correct myopia or …

[HTML][HTML] Transepithelial Photorefractive Keratectomy

C Way, MG Elghobaier, MA Nanavaty - Vision, 2024 - mdpi.com
The type and nature of refractive surgery procedures has greatly increased over the past few
decades, allowing for almost all patient populations to be treated to extremely high …

Corneal remodeling after myopic SMILE versus FS-LASIK: a spatial analysis of short-and mid-term corneal thickness, volume, and shape changes

A Lazaridis, B Spiru, E Giallouros, K Droutsas… - Cornea, 2022 - journals.lww.com
Purpose: To evaluate the short-and mid-term changes of corneal thickness spatial profile
(CTSP), corneal volume distribution (CVD), and corneal asphericity after small-incision …

In vivo measurements of thermal load during ablation in high-speed laser corneal refractive surgery

D de Ortueta, T Magnago, N Triefenbach… - Journal of Refractive …, 2012 - journals.healio.com
PURPOSE: To evaluate the thermal load of ablation in high-speed laser corneal refractive
surgery with the AMARIS excimer laser (SCHWIND eye-tech-solutions). METHODS: Thermal …

New asymmetric centration strategy combining pupil and corneal vertex information for ablation procedures in refractive surgery: theoretical background

S Arba Mosquera, T Ewering - Journal of Refractive Surgery, 2012 - journals.healio.com
PURPOSE: To describe a method for centering ablation profiles considering pupil center
and corneal vertex information simultaneously. METHODS: Novel ablation profiles were …

[HTML][HTML] High-speed recording of thermal load during laser trans-epithelial corneal refractive surgery using a 750 Hz ablation system

D De Ortueta, S Arba-Mosquera, T Magnago - Journal of optometry, 2019 - Elsevier
Purpose To evaluate the temperature rise of human cornea during trans-epithelial
photorefractive keratectomy (trans-PRK) with a 750 Hz excimer laser employing Intelligent …

[HTML][HTML] Optimum laser beam characteristics for achieving smoother ablations in laser vision correction

S Verma, J Hesser… - … Ophthalmology & Visual …, 2017 - iovs.arvojournals.org
Purpose: Controversial opinions exist regarding optimum laser beam characteristics for
achieving smoother ablations in laser-based vision correction. The purpose of the study was …

Assessing the local temperature of human cornea exposed to surface ablation by different laser refractive-surgery devices: a numerical comparative study

I Abdelhalim, O Hamdy, AA Hassan… - Lasers in Medical Science, 2021 - Springer
To evaluate the local temperature at corneal tissue after applying single laser pulse from six
commercial devices; Medilex™, Katana laser-soft, MEL90, Technolas-Teneo317, Alcon …

Analysis of the change in peak corneal temperature during excimer laser ablation in porcine eyes

SA Mosquera, S Verma - Journal of Biomedical Optics, 2015 - spiedigitallibrary.org
The objective is to characterize the impact of different ablation parameters on the thermal
load during corneal refractive surgery by means of excimer laser ablation on porcine eyes …

An optical prototype for simulating the laser delivery method in a typical LASIK device

I Abdelhalim, O Hamdy - Education and Training in Optics and …, 2021 - opg.optica.org
Conference title, upper and lower case, bolded, 18 point type, centered Page 1 An Optical
Prototype for Simulating the Laser Delivery Method in a Typical LASIK Device Ibrahim …