ICRH-related impurity source and control across experiments in H, D, T plasmas at JET-ILW

A Chomiczewska, W Gromelski, I Ivanova-Stanik… - Nuclear …, 2023 - iopscience.iop.org
The experimental and theoretical analysis were focused on experiments conducted to
assess the effect of plasma isotopes, protium (H), deuterium (D), and tritium (T) on Ion …

[HTML][HTML] Fpga and embedded systems based fast data acquisition and processing for gem detectors

WM Zabołotny, G Kasprowicz, K Poźniak… - Journal of Fusion …, 2019 - Springer
Gas electron multiplier (GEM) detectors (Sauli in Nucl Instrum Methods Phys Res A 805: 2–
24, 2016. https://doi. org/10.1016/j. nima. 2015.07. 060 (special issue in memory of Glenn F …

Latency and throughput of online processing in soft x-ray GEM-based measurement system

P Linczuk, R Krawczyk, A Wojenski… - Journal of …, 2019 - iopscience.iop.org
The paper presents latency and performance study of the monitoring system for plasma
impurities radiation in a tokamak. The developed solution measures radiation in Soft X-Ray …

Development of vacuum ultraviolet spectroscopy for measuring edge impurity emission in the EAST tokamak

H Zhang, LYU Bo, HE Liang, S Yongcai… - Plasma Science and …, 2020 - iopscience.iop.org
The dominant wavelength range of edge impurity emissions moves from the visible range to
the vacuum ultraviolet (VUV) range, as heating power increasing in the Experimental …

Measurement capabilities upgrade of GEM soft X-ray measurement system for hot plasma diagnostics

P Linczuk, A Wojenski, P Kolasinski… - … Journal of Electronics …, 2021 - yadda.icm.edu.pl
The paper presents improvements of the developed system for hot plasma radiation
measurement in the soft X-ray range based on a Gas Electron Multiplier (GEM) detector …

Communication model for multi-level control, management, and acquisition firmware-software implementations for tokamak plasma diagnostics systems

A Wojenski, P Linczuk, R Krawczyk… - … , Industry, and High …, 2019 - spiedigitallibrary.org
The paper describes the communication model implemented for tokamak plasma
diagnostics systems. The approach was tested for the SXR measurement system working …

Synchronization between computation and acquisition parts in the GEM detector-based measurement system

P Linczuk, WM Zabolotny, A Wojenski… - … , Industry, and High …, 2019 - spiedigitallibrary.org
The presented system is used for monitoring of the plasma impurities in the tokamak. It is
done by measuring radiation in Soft X-Ray range with the use of a GEM-based detector …