Matlab/simulink pulse-echo ultrasound system simulator based on experimentally validated models

T Kim, S Shin, H Lee, H Lee, H Kim… - IEEE transactions on …, 2015 - ieeexplore.ieee.org
A flexible clinical ultrasound system must operate with different transducers, which have
characteristic impulse responses and widely varying impedances. The impulse response …

Low cost ultrasound imaging device that uses optimal-lag pulse shaping filters

M Fomitchev, Y Grigorashvily… - 1999 IEEE Ultrasonics …, 1999 - ieeexplore.ieee.org
A new low-cost ultrasound imaging apparatus that uses optimal-lag pulse shaping filters
was developed. The device comprises a personal computer with MMX CPU, a PCI …

[PDF][PDF] Double element ultrasonic piezoceramic transducer modeling with VHDL-AMS: application to B/A nonlinear ultrasonic parameter measurement in pulse-echo …

R Guelaz, D Kourtiche, M Nadi, P Roth - Electronic Journal, Technical …, 2005 - ejta.org
This paper presents an ultrasonic transducer modeling with VHDL-AMS standard (Very High
speed integrated circuits Hardware Description Language–Analog and Mixed Signal) …

Edge-connected 2 dimensional array composed of nonlinear acoustic devices

N Yatame, Y Tamura, H Yanagida… - Japanese journal of …, 2002 - iopscience.iop.org
We propose an alternative 2 Dimensional acoustical array transducer which enables one to
generate an arbitrary transmitting beam with a very small number of signal channels. The …

Volumetric imaging with an amplitude-steered array

CH Frazier, WJ Hughes, WD O'Brien Jr - The Journal of the Acoustical …, 2002 - pubs.aip.org
Volumetric acoustic imaging is desirable for the visualization of underwater objects and
structures; however, the implementation of a volumetric imaging system is difficult due to the …

Parametric evaluation of NDE pulsed ultrasonic responses including relevant realistic inductive and non-linear piezoelectric & electronic phenomena

A Ruíz, A Ramos, A Azbaid - 2013 IEEE International …, 2013 - ieeexplore.ieee.org
Global responses (efficiency, spatial resolution and dynamic range) of piezoelectric
equipment for ultrasonic NDE also depend on the related high-voltage driving-receiving …

Statistical Manufacturing Model of Printing Technology

NS Kim, S Luna, JH Lee… - Journal of …, 2013 - asmedigitalcollection.asme.org
There has been an evident increase in the demand for accurate and complex patterns for
particles used in microsized electronic devices. Direct printing technology has been …

Spice model of a piezo-electric transducer for pulse-echo system

S Khan, W Taube, N Yogeswaran… - … 11th Conference on …, 2015 - ieeexplore.ieee.org
Pulse-echo system is the most widely used equipment in non-destructive testing (NDT).
Herein we present the SPICE implementation of a piezo-electric transducer for pulseecho …

Análisis inverso de señales ultrasónicas aplicado a la caracterización de materiales en capas

MG Messineo - 2014 - rinfi.fi.mdp.edu.ar
La caracterización de un material puede consistir en identificar propiedades del mismo, o
bien, detectar discontinuidades, localizarlas y dar a conocer su naturaleza (poros, fracturas …

Diagnostic ultrasound for the imaging of teeth: a comparison between experimental results and simulation models

SR Ghorayeb, E Maione - 2000 IEEE Ultrasonics Symposium …, 2000 - ieeexplore.ieee.org
Diagnostic ultrasound is being applied to teeth in order to detect cavities, decay, fractures
and even early indication of abscesses. Ultrasonic waves are particularly sensitive to tight …