[HTML][HTML] Detection Method of Partial Discharge on Transformer and Gas-Insulated Switchgear: A Review

Z Faizol, F Zubir, NM Saman, MH Ahmad, MKA Rahim… - Applied Sciences, 2023 - mdpi.com
The detection of partial discharge (PD) activities in high-voltage equipment can be
conducted according to several mechanisms of signal detection, including electromagnetic …

[HTML][HTML] Diagnosis of insulation condition of MV switchgears by application of different partial discharge measuring methods and sensors

F Álvarez Gómez, R Albarracín-Sánchez… - Sensors, 2018 - mdpi.com
Partial discharges (PD) measurement provides valuable information for the condition
assessment of the insulation status of high-voltage (HV) electrical installations. During the …

Review on partial discharge detection techniques related to high voltage power equipment using different sensors

MM Yaacob, MA Alsaedi, JR Rashed, AM Dakhil… - Photonic sensors, 2014 - Springer
When operating an equipment or a power system at the high voltage, problems associated
with partial discharge (PD) can be tracked down to electromagnetic emission, acoustic …

Recent trend of the partial discharge measurement technique using the UHF electromagnetic wave detection method

M Hikita, S Ohtsuka… - IEEJ Transactions on …, 2007 - Wiley Online Library
The ultra high frequency (UHF) electromagnetic wave detection method has been widely
studied and used in partial discharge (PD) measurement and as a diagnostic technique for …

[PDF][PDF] Sensitivity evaluation of different types of PD sensors for UHF-PD-measurements

A Troeger, U Riechert, S Burow… - Proc. Int. Conf. Condition …, 2010 - researchgate.net
Ultra high frequency (UHF) partial discharge detection is a common on-site insulation
diagnosis technique for gas-insulated switchgear (GIS) that has increasingly acquired …

New aspects of UHF PD diagnostics on gas-insulated systems

S Okabe, G Ueta, H Hama, T Ito… - IEEE Transactions on …, 2014 - ieeexplore.ieee.org
Gas insulated switchgears (GIS) have been increasingly introduced as main substation
equipment since the late 1960s thanks to their high reliability, safety, and compactness. The …

Practical experience in on-line partial discharge measurements of MV switchgear systems

Z Berler, I Blokhintsev, A Golubev… - … Record of the 2000 …, 2000 - ieeexplore.ieee.org
On-line partial discharge (PD) monitoring has proved to he a fast, convenient, reliable and
cost-effective tool in determining numerous areas of insulation deterioration within medium …

Determination of type of partial discharge in cubicle-type gas insulated switchgear (C-GIS) using artificial neural network

TR Sukma, U Khayam, R Sugawara… - … and Diagnosis (CMD …, 2018 - ieeexplore.ieee.org
Partial discharge (PD) measurement is performed as one of diagnostic tool for condition
monitoring in cubicle-type gas insulated switchgear (C-GIS). This paper presents artificial …

Partial discharge detection using acoustic and optical methods in high voltage power equipments: a review

MAR Al Saedi, MM Yaacob - Advanced Materials Research, 2014 - Trans Tech Publ
There is a high risk of insulation system dielectric instability when partial discharge (PD)
occurs. Therefore, measurement and monitoring of PD is an important preventive tool to …

UHF PD detection in gas-insulated switchgear-suitability and sensitivity of the UHF method in comparison with the IEC 270 method

N De Kock, B Coric, R Pietsch - IEEE Electrical Insulation …, 1996 - ieeexplore.ieee.org
UHF partial discharge detection in gas-insulated switchgear (GIS) has advantages over the
conventional method. For example, UHF PD detection allows the suppression of high …