Seismic rehabilitation of deficient exterior concrete frame joints

A Ghobarah, T El-Amoury - Journal of composites for construction, 2005 - ascelibrary.org
The performance of rehabilitated reinforced concrete beam-column joints was compared
with the response of existing joints designed to preseismic codes to assess proposed …

[PDF][PDF] Repair and strengthening of reinforced concrete beam-column joints: State of the art

M Engindeniz, LF Kahn, Z Abdul-Hamid - ACI structural journal, 2005 - academia.edu
The latest report by Joint ACI-ASCE Committee 352 (ACI 352R-02) states that joints in
structures built before the development of current design guidelines need to be studied in …

Effectiveness of reinforcement details in exterior reinforced concrete beam-column joints for earthquake resistance

CVR Murty, DC Rai, KK Bajpai, SK Jain - Structural Journal, 2003 - concrete.org
This paper describes an experimental study of beam-column joints in frames common in
preseismic code/gravity-designed reinforced concrete (RC) frame buildings. Exterior RC …

[PDF][PDF] Behavior of deficient joints with plain bars and low-strength concrete

I Bedirhanoglu, A Ilki, S Pujol, N Kumbasar - ACI Structural Journal, 2010 - academia.edu
Two series of tests of exterior beam-column joints were conducted. In the first series of tests,
the longitudinal reinforcement of the beam was anchored in the joint with 90-degree hooks …

Lateral load response of strengthened reinforced concrete beam-to-column joints

AG Tsonos - Seismic Design and Practice into the Next Century, 2022 - taylorfrancis.com
Two test series were conducted to determine the effectiveness of UNIDO Manual guidelines
for repair and strengthening of beam column joints damaged by severe earthquakes. Two …

Seismic behavior of reinforced concrete interior beam-wide column joints repaired using FRP

B Li, Q Kai - Journal of Composites for Construction, 2011 - ascelibrary.org
To prevent the casualties that can result from the collapse of earthquake-damaged
structures, it is important that structures be rehabilitated as soon as possible. This paper …

Seismic performance of reinforced concrete building exterior joints with substandard details

CP Pantelides, J Hansen, MJ Ameli… - Journal of Structural …, 2017 - Taylor & Francis
Beam-column joints are important components of the seismic-force-resisting system in
reinforced concrete (RC) frame buildings. A majority of older buildings have serious …

Seismic rehabilitation of beam–column joint using GFRP sheets

T El-Amoury, A Ghobarah - Engineering Structures, 2002 - Elsevier
Techniques for upgrading reinforced concrete beam–column joints are proposed. The test
specimens represent a typical joint that was built in accordance to pre-1970s' codes. The …

Seismic behavior of as-built, ACI-complying, and CFRP-repaired exterior RC beam-column joints

YA Al-Salloum, TH Almusallam, SH Alsayed… - Journal of composites …, 2011 - ascelibrary.org
In this paper, the efficiency and effectiveness of carbon-fiber-reinforced polymer (CFRP)
sheets for upgrading the shear strength and ductility of a seismically deficient exterior beam …

Seismic load tests on interior and exterior beam-column joints with substandard reinforcing details

S Hakuto, R Park, H Tanaka - Structural Journal, 2000 - concrete.org
Simulated seismic load tests on reinforced concrete one-way interior and exterior beam-
column joints with substandard reinforcing details typical of buildings constructed before the …