A novel strategy for reducing inrush current of three-phase transformer considering residual flux

S Fang, H Ni, H Lin, SL Ho - IEEE Transactions on Industrial …, 2016 - ieeexplore.ieee.org
Proper use of phase-controlled switching technology by controlling the making or breaking
of the circuit breaker (CB) at predetermined phase angles of current or voltage can improve …

Flux error function based controlled switching method for minimizing inrush current in 3-phase transformer

P Pachore, Y Gupta, S Anand, S Sarkar… - … on Power Delivery, 2020 - ieeexplore.ieee.org
Energization of the transformer leads to large magnetizing current called inrush current. It
results in reduction in transformer life, reduction in circuit breaker life, and power quality …

Reduction of three-phase transformer inrush currents using controlled switching

J Mitra, X Xu, M Benidris - IEEE Transactions on Industry …, 2019 - ieeexplore.ieee.org
This article proposes a new approach for reducing inrush currents in three-phase three-
legged stacked-core power transformers. Although magnitudes of inrush currents may not …

Microcontroller-based switch for three-phase transformer inrush current minimization

OA Mahgoub - V IEEE International Power Electronics …, 1996 - ieeexplore.ieee.org
This paper presents a novel method for the minimization of three-phase transformer inrush
current in the case of sustained switching-on operations. First, a simple mathematical model …

A simplified phase-controlled switching strategy for inrush current reduction

H Ni, S Fang, H Lin - IEEE Transactions on Power Delivery, 2020 - ieeexplore.ieee.org
High inrush current severely threats the safe operation of the power system and
transformers, which may lead to mal-operation of overcurrent protection device, internal …

Controlled switching strategies for transformer inrush current reduction: A comparative study

R Cano-González, A Bachiller-Soler… - Electric Power Systems …, 2017 - Elsevier
Transformer inrush current can be efficiently mitigated by controlled switching. For
energization of three-phase transformers, several strategies have been developed that …

Inrush current reduction by a point-on-wave energization strategy and sequential phase shifting in three-phase transformer

A Yahiou, H Mellah, A Bayadi - International Journal of Engineering, 2022 - ije.ir
The main goal of this work is the mitigation of inrush current in a three-phase transformer.
This inrush current appears when energizing a no-load or lightly loaded transformer. It can …

Modeling and simulation, and their validation of three-phase transformers with three legs under DC bias

EF Fuchs, Y You, DJ Roesler - IEEE Transactions on Power …, 1999 - ieeexplore.ieee.org
This paper proposes a new model for three-phase transformers with three legs with and
without task under DC bias based on electric and magnetic circuit theory. For the calculation …

[PDF][PDF] Prefluxing technique to mitigate inrush current of three-phase power transformer

PJ Kotak, J Singh - vol, 2013 - academia.edu
At the time of transformer energization, a high current will be drawn by the transformer. This
current is called transient inrush current and it may rise to ten times the nominal full load …

Three-phase transformer inrush current reduction strategy based on prefluxing and controlled switching

Y Pan, X Yin, Z Zhang, B Liu, M Wang, X Yin - IEEE Access, 2021 - ieeexplore.ieee.org
Inrush current with high amplitude is generated when the transformer is energized. On the
one hand, it will have a negative impact on the safety of the transformer itself, and even …