Effects of variation of axial load and bidirectional loading on seismic performance of GFRP retrofitted reinforced concrete exterior beam-column joints

U Akguzel, S Pampanin - Journal of Composites for Construction, 2010 - ascelibrary.org
Most of the experimental studies available in literature on the seismic assessment and
retrofit of existing, poorly detailed, reinforced concrete (RC) beam-column joints, typical of …

[PDF][PDF] Seismic performance of FRP retrofitted exterior RC beam-column joints under varying axial and bidirectional loading

U Akguzel - 2011 - ir.canterbury.ac.nz
Most of the experimental studies available in literature on the seismic assessment and
retrofit of existing, poorly detailed, reinforced concrete (RC) beam-column joints typical of …

Seismic retrofit of joints of a full-scale 3D reinforced concrete frame with FRP composites

C Cosgun, M Cömert, C Demir, A İlki - Journal of Composites for …, 2019 - ascelibrary.org
Postearthquake reconnaissance studies show that the beam-column joints of substandard
reinforced concrete buildings (particularly the corner joints) may fail to resist the demanded …

Experimental investigation of exterior RC beam-column joints retrofitted with FRP systems

C Del Vecchio, M Di Ludovico, A Balsamo… - … of Composites for …, 2014 - ascelibrary.org
Premature brittle failures because of seismic actions strongly affect the behavior of existing
reinforced concrete (RC) structural systems. They commonly involve exterior beam-column …

Seismic strengthening of severely damaged beam-column RC joints using CFRP

R Garcia, Y Jemaa, Y Helal, M Guadagnini… - … of Composites for …, 2014 - ascelibrary.org
This article investigates the seismic behavior of three full-scale exterior reinforced concrete
(RC) beam-column joints rehabilitated and strengthened with externally bonded carbon fiber …

Experimental evaluation of seismic performance of interior RC beam-column joints strengthened with FRP composites

K Allam, AS Mosallam, MA Salama - Engineering Structures, 2019 - Elsevier
Lack of joint confinement for the majority of pre-1970 reinforced concrete (RC) frame
construction has resulted in weakening the link between the column and the beam and …

Seismic performance of exterior RC beam–column joints retrofitted using various retrofit solutions

GT Truong, NH Dinh, JC Kim, KK Choi - International Journal of Concrete …, 2017 - Springer
Beam–column joints in existing concrete buildings might not satisfy the design requirements
for seismic reinforcement details specified in current seismic design codes. Thus, in this …

Seismic response of FRP-upgraded exterior RC beam-column joints

SH Alsayed, YA Al-Salloum, TH Almusallam… - … of Composites for …, 2010 - ascelibrary.org
Shear failure of exterior beam-column joints is identified as the principal cause of collapse of
many moment-resisting frame buildings during recent earthquakes. Effective and …

Precast fiber reinforced cementitious composites for seismic retrofit of deficient RC joints–a pilot study

I Bedirhanoglu, A Ilki, N Kumbasar - Engineering Structures, 2013 - Elsevier
The objective of this study was to investigate the seismic behavior of deficient reinforced
concrete exterior beam–column joints constructed with low-strength concrete and plain …

Seismic response of interior RC beam-column joints upgraded with FRP sheets. I: Experimental study

YA Al-Salloum, TH Almusallam - Journal of Composites for …, 2007 - ascelibrary.org
In this paper, efficiency and effectiveness of carbon fiber-reinforced polymers (CFRP) in
upgrading the shear strength and ductility of seismically deficient beam-column joints have …