[PDF][PDF] Investigation of torsional amplification of inelastic seismic demand in plan asymmetric buildings

Y Hu, E Lumantarna, N Lam, HH Tsang - aees.org.au
Torsion-induced seismic response amplification is a major concern for the seismic safety of
a plan-asymmetric building subjected to the earthquake. Particularly, the undesirable …

[PDF][PDF] Earthquake induced torsion in buildings: critical review and state of the art

SA Anagnostopoulos, MT Kyrkos… - Earthquakes and …, 2015 - researchgate.net
The problem of earthquake induced torsion in buildings is quite old and although it has
received a lot of attention in the past several decades, it is still open. This is evident not only …

[PDF][PDF] Accidental and natural torsion in earthquake response and design of buildings

AK Chopra, JC De la Llera - Eleventh world conference on earthquake …, 1996 - iitk.ac.in
Considering that a comprehensive review of past work in this field is available, this paper
focuses on the description of two recently developed procedures to incorporate the effects of …

Review of the torsional coupling of asymmetrical wall-frame buildings

NTK Lam, JL Wilson, GL Hutchinson - Engineering structures, 1997 - Elsevier
Significant dynamic torsional amplifications are known to occur in asymmetrical buildings
when subject to earthquake excitations. The torsional effects are commonly taken into …

New Behavioural Trends of Plan Asymmetric Limited Ductile Buildings Revealed by Incremental Dynamic Analysis

Y Hu, E Lumantarna, N Lam… - Journal of Earthquake …, 2024 - Taylor & Francis
The drift demand of plan-asymmetric buildings in low seismicity regions was studied by
employing Incremental Dynamic Analysis to track the influence of torsion. A stepped …

A Phenomenological study on inelastic torsion caused by nonlinear behavior changes during earthquake excitations

SB Beheshti-Aval, S Keshani - Civil Engineering Infrastructures Journal, 2014 - ceij.ut.ac.ir
Torsion of many symmetric structures, which were designed based on the seismic codes, is
due to their asymmetricity induced during inelastic behavior. Although the structure was …

[PDF][PDF] Ratio of Torsion (ROT): An index for assessing the global induced torsion in plan irregular buildings

CG Stathi, NP Bakas, ND Lagaros… - Earthquakes and …, 2015 - researchgate.net
Due to earthquakes, many structures suffered extensive damages that were attributed to the
torsional effect caused by mass, stiffness or strength eccentricity. Due to this type of …

[PDF][PDF] Effects of irregularities on the seismic response of a medium rise structure

A Titiksh - ASIAN JOURNAL OF CIVIL ENGINEERING (BHRC), 2017 - academia.edu
Structural engineers often come across buildings, which exhibit certain degrees of plan
asymmetry. It may in fact even exist in a nominally symmetric structure, because of the …

On the inelastic torsional response of single‐storey structures under bi‐axial excitation

I Peruš, P Fajfar - Earthquake engineering & structural …, 2005 - Wiley Online Library
An attempt has been made to explore the general trends in the seismic response of plan‐
asymmetric structures without any restrictions imposed by a particular code. Systems with …

[HTML][HTML] The effect of various design codes and dynamic magnification on buildings with torsional irregularity

KH Lee, SH Jeong, S Han, KS Kim - Journal of Vibroengineering, 2016 - extrica.com
Seismic provisions have utilized design eccentricities to reduce planar irregularities in
lateral stiffness of buildings. In calculating a design eccentricity, the torsional amplification …