A precast beam-column connection using metallic damper as connector: Experiment and application

D Li, C Wu, Y Zhou, W Luo, W Lie - Journal of Constructional Steel …, 2021 - Elsevier
The beam-column connection is the most vulnerable part of the precast moment-resisting
frame in earthquakes. A novel beam-column connection using a metallic damper is …

A detachable configuration for the precast beam-column connection using metallic damper as connector: Experimental investigation

C Wu, C Zhu, D Li, C Li, Y Zhou, W Lie, C Wu… - Journal of Building …, 2023 - Elsevier
A beam-column connection with satisfactory seismic performance and assembly efficiency is
preferred in prefabricated structures. An evolved detachable configuration for the precast …

Experimental study on two innovative ductile moment-resisting precast concrete beam-column connections

MBT Beni, M Madhkhan - Structures, 2022 - Elsevier
The use of precast concrete elements in construction leads to increased output quality,
better product control, cost savings, and reduced construction time. The main problem of …

Bolted beam-to-column connection with buckling-restrained round steel bar dampers

H Tagawa, Y Nagoya, X Chen - Journal of Constructional Steel Research, 2020 - Elsevier
In the design of steel building frames, comprehensive consideration is required to determine
beam-to-column connections because their characteristics largely influence the …

Seismic performance of a novel prefabricated beam-to-column steel joint considering buckling behaviour of dampers

Y Qi, J Teng, Q Shan, J Ding, Z Li, C Huang, H Xing… - Engineering …, 2021 - Elsevier
A novel prefabricated beam-to-column steel joint (PSJ) for precast concrete structures was
proposed in this study. The joint had the advantages of easier to fabricate and more …

A precast beam-column joint using an innovative friction damper as a connector: Experimental and numerical study

A Qi, X Liu, R Xu, X Yan - Structures, 2022 - Elsevier
The beam-column connection is the weakest link of the precast concrete (PC) frame in
earthquakes. An innovative friction damper (FD) as connector is proposed in this paper to …

Experimental investigation of prefabricated beam-to-column steel joints for precast concrete structures under cyclic loading

Z Li, Y Qi, J Teng - Engineering Structures, 2020 - Elsevier
In this study, a novel prefabricated beam-to-column steel joint suitable for precast concrete
structures was developed. The proposed steel joint with dampers could replace cast-in-situ …

Cyclic loading of ductile precast concrete beam-column connection

AR Khaloo, H Parastesh - Structural Journal, 2003 - concrete.org
In this study, a simple moment-resisting precast concrete beamcolumn connection is
proposed for highly seismic regions. An experimental study was carried out to investigate …

Ductile beam-column connection in precast concrete

SU Pillai, DW Kirk - Journal Proceedings, 1981 - concrete.org
A satisfactory design for such a connection was developed and the performance of the
connection experimental/y investigated. A total of I 1 tests were conducted on full scale …

Hysteretic behavior of replaceable steel plate damper for prefabricated joint with earthquake resilience

J Ye, G Yan, R Liu, P Xue, D Wang - Journal of Building Engineering, 2022 - Elsevier
Prefabricated structures are widely used in civil infrastructure, attributed to the advantages of
environmental sustainability, easy in-situ operation, short construction period and low-cost …