Characterization of Micro-Threaded Stem Taper Surfaces of Cementless Hip Endoprostheses

D Dolinar, B Kocjančič, K Avsec, B Šetina Batič… - Materials, 2024 - mdpi.com
We investigated micro-threaded stem taper surface and its impact on premature failures,
aseptic loosening, and infection in cementless hip endoprostheses. Our study focused on …

Do Surface Topography and Contact Area Effect Fretting Corrosion Behaviour of the Modular Taper Interface in Total Hip Replacements?

A Panagiotidou, J Meswania, J Hua… - Orthopaedic …, 2013 - boneandjoint.org.uk
Introduction: There has been widespread concern regarding the adverse tissue reactions
after metal-on-metal (MoM) total hip replacements (THR). Concerns have also been …

Variability in stem taper surface topography affects the degree of corrosion and fretting in total hip arthroplasty

KE Stockhausen, C Riedel, AV Belinski, D Rothe… - Scientific Reports, 2021 - nature.com
Degradation at the modular head-neck interface in total hip arthroplasty (THA) is
predominately expressed in the form of corrosion and fretting, potentially causing peri …

Surface analysis on revised hip implants with stem taper for wear and failure incidence evaluation: A first investigation

S Affatato, A Ruggiero - Measurement, 2019 - Elsevier
Background As revision surgeries of total hip arthroplasty are going to increase, success or
failure of revised implants is a fundamental aspect in the orthopaedic field. Today, slight is …

Taper corrosion in total hip arthroplasty–How to assess and which design features are crucial?

U Mueller, T Bormann, S Schroeder… - Journal of the …, 2022 - Elsevier
Background In total hip replacement, wear and corrosion arising from modular taper
connections have increasingly become a serious clinical concern. Previous studies led to …

Same same but different? 12/14 stem and head tapers in total hip arthroplasty

U Mueller, S Braun, S Schroeder, R Sonntag… - The Journal of …, 2017 - Elsevier
Background Taper corrosion has been identified to be a major concern in total hip
arthroplasty during the past years. So far, the mechanisms that lead to taper corrosion in …

Enhanced wear and corrosion in modular tapers in total hip replacement-an in-vitro biomechanical study

J Meswania, G Biring, C Wylie, J Hua… - Orthopaedic …, 2012 - boneandjoint.org.uk
Introduction The National Joint Registry has recently identified failure of large head metal on
metal hip replacements. This failure is associated with the high torque at the interface of …

Do stem taper microgrooves influence taper corrosion in total hip arthroplasty? A matched cohort retrieval study

CM Arnholt, DW MacDonald, RJ Underwood… - The Journal of …, 2017 - Elsevier
Background Previous studies identified imprinting of the stem morphology onto the interior
head bore, leading researchers to hypothesize an influence of taper topography on …

Head taper corrosion causing head bottoming out and consecutive gross stem taper failure in total hip arthroplasty

MM Morlock, EC Dickinson, KP Günther, D Bünte… - The journal of …, 2018 - Elsevier
Background Taper corrosion in total hip arthroplasty for bearings with metal heads against
polyethylene has developed from an anecdotal observation to a clinical problem. Increased …

Taper corrosion: a complication of total hip arthroplasty

MM Morlock, R Hube, G Wassilew… - EFORT open …, 2020 - eor.bioscientifica.com
The focus on taper corrosion in modular hip arthroplasty increased around 2007 as a result
of clinical problems with large-head metal-on-metal (MoM) bearings on standard stems …