Small-signal modeling and multivariable PI control design of VSC-HVDC transmission link

JK Pradhan, A Ghosh, CN Bhende - Electric Power Systems Research, 2017 - Elsevier
This paper employs a multivariable PI (proportional-integral) controller for inner-loop control
and SISO (single-input single-output) PI controllers for outer-loop control for a VSC-HVDC …

[HTML][HTML] VSC controllers for multiterminal HVDC transmission system: A comparative study

MI Hossain, M Shafiullah, M Abido - Arabian Journal for Science and …, 2020 - Springer
Voltage source converter (VSC)-based multiterminal high-voltage direct current (HVDC)
systems received widespread attention throughout the world for grid integration of …

IDA‐PB control design for VSC‐HVDC transmission based on PCHD model

X Fan, L Guan, C Xia, T Ji - International Transactions on …, 2015 - Wiley Online Library
An interconnection and damping assignment passivity‐based (IDA‐PB) control design is
proposed to improve the dynamic performance of voltage source converter high‐voltage …

Comparison of PI and PR current controllers applied on two-level VSC-HVDC transmission system

A Manoloiu, HA Pereira, R Teodorescu… - 2015 IEEE …, 2015 - ieeexplore.ieee.org
This paper analyzes differences between αβ and dq reference frames regarding the control
of two-level VSC-HVDC current loop and dc-link voltage outer loop. In the first part, voltage …

Performance enhancement and robustness assessment of VSC–HVDC transmission systems controllers under uncertainties

HS Ramadan, H Siguerdidjane, M Petit… - International Journal of …, 2012 - Elsevier
This paper addresses two different robust nonlinear control methodologies based Sliding
Mode Control (SMC) for the Voltage Source Converters (VSC) High Voltage Direct Current …

Modeling and simulation of VSC-HVDC with current deadbeat control

X Fu, LA Dessaint, R Gagnon, K Zhou… - … on Electrical Machines …, 2011 - ieeexplore.ieee.org
In this paper, a double-loop control scheme is proposed for the VSC-HVDC transmission
system connecting two AC grids. A conventional PI controller is used in the outer loop and a …

Control design and operational characteristics comparation for VSC-HVDC supplying active/passive networks

J Xu, C Zhao, B Zhang - 2011 6th IEEE Conference on …, 2011 - ieeexplore.ieee.org
The transient mathematical models of two VSC-HVDC systems which are supplying active
and passive networks respectively are developed in dq synchronous reference frames. All …

Research on PI controller tuning for VSC-HVDC system

YP Li, SC Yang, K Wang, D Zeng - … International Conference on …, 2011 - ieeexplore.ieee.org
Dual closed loop structure is often adopted in VSC-HVDC control system, and the PI
controller design and parameters tuning can be regarded as the core content in the control …

Advanced control strategies of VSC based HVDC transmission system: Issues and potential recommendations

MA Hannan, I Hussin, PJ Ker, MM Hoque… - Ieee …, 2018 - ieeexplore.ieee.org
The converters and their control strategies play an important role in converting, transmitting,
and improving the performance of high-voltage direct current (HVDC) system. There are …

Nonlinear control scheme for VSC-HVDC transmission systems

M Rashed, SMA El-Anwar… - 2008 12th International …, 2008 - ieeexplore.ieee.org
This paper presents a nonlinear control scheme for VSC-HVDC transmission system. The
design of the proposed nonlinear controller has been performed in a rotating reference …