Structural health monitoring of the Basilica S. Maria di Collemaggio

V Gattulli, F Graziosi, F Federici… - … and Applications in …, 2013 - api.taylorfrancis.com
The work deals with the main findings obtained during the development of a permanent
structural health monitoring system for a monumental church, the Basilica S. Maria di …

Long-term structural monitoring of the damaged Basilica S. Maria di Collemaggio through a low-cost wireless sensor network

F Potenza, F Federici, M Lepidi, V Gattulli… - Journal of Civil …, 2015 - Springer
The work presents the inter-disciplinary multi-year project focused on the permanent seismic
monitoring of a historical structure, the Basilica S. Maria di Collemaggio, by means of an …

On the monitoring of historic Anime Sante church damaged by earthquake in L'Aquila

S Russo - Structural control and health monitoring, 2013 - Wiley Online Library
The paper shows the activity of a 2‐year static and dynamic monitoring activity to check the
structural response and the actual level of damage of a historic church hit by earthquake in …

[PDF][PDF] Dynamic testing and health monitoring via wireless sensor networks in the post-earthquake assessment of structural condition at L'Aquila

E Antonacci, A Ceci, A Colarieti, V Gattulli… - 8th European …, 2011 - bwk.kuleuven.be
The use of vibration measures during ambient dynamic testing or integrated within
permanent structural health monitoring systems may play a fundamental role in urban areas …

Post-earthquake controls and damage detection through structural health monitoring: applications in l'Aquila

F Lorenzoni, M Caldon, F da Porto, C Modena… - Journal of Civil …, 2018 - Springer
The paper presents structural health monitoring (SHM) activities performed on some
representative cultural heritage (CH) buildings in the city of l'Aquila after the strong …

Structural health monitoring of a historic masonry tower

C Gentile, M Guidobaldi, A Saisi - 2015 IEEE Workshop on …, 2015 - ieeexplore.ieee.org
The paper summarizes the results of the first 15 months of continuous dynamic monitoring of
the Gabbia tower in Mantua. After the Italian seismic events of May 2012 a wide …

Continuous monitoring of a challenging heritage tower in Monza, Italy

A Saisi, C Gentile, A Ruccolo - Journal of Civil Structural Health …, 2018 - Springer
A recent survey of the historic complex of “Santa Maria del Carrobiolo” in Monza (Italy)
highlighted that two sides of the bell-tower are directly supported by the load-bearing walls …

Dynamic Identification & Monitoring of the churches of St. Biagio and St. Giuseppe in l'Aquila

F Casarin, F Lorenzoni, K Islami… - … Vibration Analysis for …, 2011 - research.unipd.it
In the framework of a wide investigation campaign carried out by the authors-together with
the Polytechnic of Milan-in the churches of St. Biagio d'Amiterno and St. Giuseppe dei …

Continuous monitoring the Cathedral of Milan: design, installation and preliminary results

C Gentile, F Canali - Proceedings, 2018 - mdpi.com
The Milan Cathedral, built between 1386 and 1813, is one of the largest masonry
monuments ever built. After a brief description of the Cathedral, the paper presents the …

Long-term monitoring of a damaged historic structure using a wireless sensor network

E Mesquita, A Arêde, N Pinto, P Antunes… - Engineering Structures, 2018 - Elsevier
Recent advances on sensing and data communication systems have allowed the
optimization of the structural health monitoring systems, as well their employment for long …