一种利用双端电气量的故障测距新算法.

张向聪, 夏经德, 陈伟利, 王波… - Journal of Xi'an …, 2016 - search.ebscohost.com
English In view of the complexity in the process of solving the fault distance, a novel fault
location algorithm of using two-terminal electric quantities is proposed, based on the method …

A New Practical Fault Location Algorithm for Two-Terminal Transmission Lines

Z Ma, XN Li, XM Zhang - Advanced Materials Research, 2012 - Trans Tech Publ
A new practical fault location algorithm using two-terminal electrical quantities is presented
in this article, which takes into account the distributed parameter line model. The analytical …

A double-terminal fault location algorithm based on precise integration method

J Yin, J Zhao, L Fan, P Hong… - 2016 9th International …, 2016 - ieeexplore.ieee.org
A novel method for fault location is proposed in this paper, which is based on fault voltages
and currents sampled synchronously on both ends of the fault line. This algorithm is based …

A precise fault location method independent of line parameters based on positive and negative sequence fault components

L Zhao, J Zhu, H Yang - Journal of Electrical Engineering & Technology, 2022 - Springer
A precise and robust fault location method based on positive and negative sequence fault
components for transmission lines is proposed, with synchro phasor data. This method …

A Method of Single Phase-to-ground Fault Section Location for Closed-loop Distribution Networks

Z Qi, R Xue - IOP Conference Series: Materials Science and …, 2019 - iopscience.iop.org
In the field of fault location technology for neutral point non-effectively grounded distribution
network, the original radial mode of operation is no longer applicable due to the gradual …

Fault-location method based on optimization for N terminal lines (N≥ 3) using asynchronous data of line terminals during-fault

F Poudineh Ebrahimi - 2017 - eprints.uoz.ac.ir
In this thesis, new and accurate algorithms for finding faults in two-terminal, threeterminal
and multi-terminal transmission lines are presented. Fault locating algorithms are converted …

Applicable range analysis of optimized single-terminal fault location algorithm

T Huang, X Dong, S Shi, B Wang - … International Conference on …, 2011 - ieeexplore.ieee.org
Impedance method and single terminal travelling wave method are analyzed in paper,
applicable scope of optimized solution is presented. Impedance method is of high …

Optimizing solution of fault location using single terminal quantities

XZ Dong, SX Shi, T Cui, Q Lu - Science in China Series E: Technological …, 2008 - Springer
This paper firstly evaluated the impedance method and traveling waves method for fault
location, and studied the robustness of fault location method based on impedance. Then it …

[HTML][HTML] A novel single-end fault location method for double-circuit transmission lines

MK Arpanahi, MH Fini, A Nateghi - … Journal of Electrical Power & Energy …, 2024 - Elsevier
A new fault location method based on single-end measurements is proposed in this paper.
The proposed method decomposes the fault location problem into two sub-problems and …

[引用][C] A new fault location algorithm with two-terminal electric quantities

X ZHANG, J XIA, W CHEN