Low-Cost Online Partial Discharge Monitoring System for Power Transformers

W Sikorski, A Wielewski - Sensors, 2023 - mdpi.com
The article presents in detail the construction of a low-cost, portable online PD monitoring
system based on the acoustic emission (AE) technique. A highly sensitive piezoelectric …

Development of acoustic emission sensor optimized for partial discharge monitoring in power transformers

W Sikorski - Sensors, 2019 - mdpi.com
The acoustic emission (AE) technique is one of the unconventional methods of partial
discharges (PD) detection. It plays a particularly important role in oil-filled power …

[HTML][HTML] On-Line partial discharge monitoring system for power transformers based on the simultaneous detection of high frequency, ultra-high frequency, and acoustic …

W Sikorski, K Walczak, W Gil, C Szymczak - Energies, 2020 - mdpi.com
The article presents a novel on-line partial discharge (PD) monitoring system for power
transformers, whose functioning is based on the simultaneous use of three unconventional …

On-line partial discharge calibration and monitoring for power transformers

AS Farag, MH Shewhdi, X Jin, C Wang… - Electric Power Systems …, 1999 - Elsevier
Partial discharge (PD) is one of the major factors causing insulation damage of power
transformers. This paper describes the development of on-line partial discharge monitoring …

Active dielectric window: A new concept of combined acoustic emission and electromagnetic partial discharge detector for power transformers

W Sikorski - Energies, 2018 - mdpi.com
The detection and location of partial discharge (PD) is of great significance in evaluating the
insulation condition of power transformers. This paper presents an active dielectric window …

Study on descriptors of acoustic emission signals generated by partial discharges under laboratory conditions and in on-site electrical power transformer

M Kunicki, A Cichoń, S Borucki - Archives of Acoustics, 2016 - acoustics.ippt.gov.pl
An acoustic emission method (AE) is widespread and often applied for partial discharge
(PD) diagnostics, mainly due to its ease of application as well as noninvasiveness and …

Sensitive online PD-measurements of onsite oil/paper-insulated devices by means of optimized acoustic emission techniques (AET)

E Grossmann, K Feser - IEEE transactions on power delivery, 2005 - ieeexplore.ieee.org
Recently developed monitoring-systems show the need as also the possibilities for online-
and offline-onsite-diagnostics. The limit in sensitivity for electrical pd-measurements …

Partial discharge monitoring in power transformers using low-cost piezoelectric sensors

B Castro, G Clerice, C Ramos, A Andreoli, F Baptista… - Sensors, 2016 - mdpi.com
Power transformers are crucial in an electric power system. Failures in transformers can
affect the quality and cause interruptions in the power supply. Partial discharges are a …

Online PD detection on high voltage underground power cables by acoustic emission

P Casals-Torrens, A González-Parada… - Procedia Engineering, 2012 - Elsevier
Acoustic waves produced by partial discharges inside in dielectric materials can be detected
using acoustic emission (AE) sensors. This detection can be analyzed in the time domain …

Intelligent condition monitoring and asset management. Partial discharge monitoring for power transformers

MD Judd, SDJ McArthur, JR McDonald… - Power Engineering …, 2002 - ieeexplore.ieee.org
Condition monitoring of power transformers is a significant issue for electrical utilities.
Research has demonstrated the efficacy of employing ultra high frequency measurement of …