Multimodality image registration by maximization of mutual information

F Maes, A Collignon, D Vandermeulen… - IEEE transactions on …, 1997 - ieeexplore.ieee.org
A new approach to the problem of multimodality medical image registration is proposed,
using a basic concept from information theory, mutual information (MI), or relative entropy, as …

Multimodal image coregistration and partitioning—a unified framework

J Ashburner, K Friston - Neuroimage, 1997 - Elsevier
This paper presents a method for the coregistration and partitioning (ie, tissue segmentation)
of brain images that have been acquired in different modalities. The basic idea is that …

Comparison and evaluation of retrospective intermodality brain image registration techniques

J West, JM Fitzpatrick, MY Wang… - Journal of computer …, 1997 - journals.lww.com
Purpose: The primary objective of this study is to perform a blinded evaluation of a group of
retrospective image registration techniques using as a gold standard a prospective, marker …

Registration of head volume images using implantable fiducial markers

CR Maurer, JM Fitzpatrick, MY Wang… - IEEE transactions on …, 1997 - ieeexplore.ieee.org
Describes an extrinsic-point-based, interactive image-guided neurosurgical system
designed at Vanderbilt University, Nashville, TN, as part of a collaborative effort among the …

Integration of functional and anatomical brain images

MA Viergever, JBA Maintz, R Stokking - Biophysical chemistry, 1997 - Elsevier
This article concerns the integration of functional and anatomical volumetric brain images.
Integration consists of two steps: matching or registration, where the images are brought into …

Evaluation of the limits of visual detection of image misregistration in a brain fluorine-18 fluorodeoxyglucose PET MRI study

JCH Wong, C Studholme, DJ Hawkes… - European journal of …, 1997 - Springer
In routine clinical work, registration accuracy is assessed by visual inspection. However, the
accuracy of visual assessment of registration has not been evaluated. This study establishes …

Estimation of intraoperative brain surface movement

DLG Hill, CR Maurer Jr, MY Wang, RJ Maciunas… - … on Computer Vision …, 1997 - Springer
It is becoming increasingly common for surgical navigation systems to be used
intraoperatively to enable the surgeon to ascertain his or her position within the patient with …

Rigid registration of CT, MR and cryosection images using a GLCM framework

M Bro-Nielsen - International Conference on Computer Vision, Virtual …, 1997 - Springer
The majority of the available rigid registration measures are based on a 2-dimensional
histogram of corresponding grey-values in the registered images. This paper shows that …

Anatomical landmark image registration: validation and comparison

KC Strasters, JA Little, J Buurman, DLG Hill… - … on Computer Vision …, 1997 - Springer
This paper describes a validation approach for (interactive) anatomical landmark registration
of CT and MR images. Eleven MR-CT image pairs were used, four of which had been …

Feasibility study of magnetic resonance imaging-guided intranasal flexible microendoscopy

DLG Hill, LA Langsaeter, PN Poynter-Smith… - Computer Aided …, 1997 - Taylor & Francis
Interventional magnetic resonance imaging (MRI) offers potential advantages over
conventional interventional modalities such as X-ray fluoroscopy, ultrasonography, and …