Rapid time-gated polarimetric Stokes imaging using photoelastic modulators

S Alali, T Yang, IA Vitkin - Optics letters, 2013 - opg.optica.org
We report a rapid time-gated full Stokes imaging approach without mechanically moving
parts, which is well-suited for biomedical applications, using two photoelastic modulators …

Optimization and tolerance analysis of a polarimeter with ferroelectric liquid crystals

A Peinado, A Lizana, J Campos - Applied optics, 2013 - opg.optica.org
We present the design of Stokes and Mueller polarimeters based on ferroelectric liquid
crystal (FLC) panels. The instrument is complete and takes time-sequential measurements …

Optimization of rapid Mueller matrix imaging of turbid media using four photoelastic modulators without mechanically moving parts

S Alali, IA Vitkin - Optical Engineering, 2013 - spiedigitallibrary.org
A new method based on four photoelastic modulators (PEMs) and a charged couple device
(CCD) camera, to rapidly image the samples' entire Mueller matrix, is proposed and …

Mueller matrix polarimetry in material science, biomedical and environmental applications

SN Savenkov - Handbook of Coherent-Domain Optical Methods …, 2013 - elibrary.ru
This chapter describes approaches to understanding the physics of the interaction of
polarized beams with natural scenes and to searching for informative and useful polarimetric …

Optimal configuration for the dual rotating-compensator Mueller matrix ellipsometer

W Du, S Liu, C Zhang, X Chen - … International Symposium on …, 2013 - spiedigitallibrary.org
The dual rotating-compensator Mueller matrix ellipsometer based on the optical
configuration PC1r (ω1) SC2r (ω2) A has been developed recently with many applications …

Polarization Sensitive Optical Imaging of Biomaterials Using a Mueller Matrix Polarimetric Algorithm.

S Firdous, W Waqas, M Idrees… - … in Engineering (Old …, 2013 - search.ebscohost.com
A complete and minimum set of necessary and sufficient conditions for a real 4⋅ 4 matrix to
be a physical Mueller matrix with forward and reverse decomposition is obtained. The …

Reduction of measurement errors with two-channel configuration in the Mueller matrix ellipsometer

W Li, S Liu, C Zhang, X Chen - … International Symposium on …, 2013 - spiedigitallibrary.org
The random noise and the systematic errors caused by azimuthal errors of the optical
elements, ie, the polarizer, the analyzer, or the compensator, would lead to measurement …

[PDF][PDF] Characterizing Mueller matrices in Polarimetry

GR Franssens - polarisation.eu
Characterizing Mueller matrices in Polarimetry Page 1 Characterizing Mueller matrices in
Polarimetry Ghislain R. Franssens Belgian Institute for Space Aeronomy Ringlaan 3, 1180 …