Long-term short implants performance: systematic review and meta-analysis of the essential assessment parameters

TMSV Gonçalves, S Bortolini, M Martinolli… - Brazilian dental …, 2015 - SciELO Brasil
Lack of standard criteria in the outcome assessment makes it difficult to draw conclusions on
the clinical performance of short implants and, under these circumstances, determine the …

Early loading of 6‐mm‐short implants with a moderately rough surface supporting single crowns–a prospective 5‐year cohort study

F Rossi, NP Lang, E Ricci, L Ferraioli… - Clinical oral implants …, 2015 - Wiley Online Library
Aim To evaluate prospectively the clinical and radiographic outcomes after 5 years of early
loading of 6‐mm implants with a moderately rough (SLA ctive®) surface supporting single …

Randomized controlled multicenter study comparing short dental implants (6 mm) versus longer dental implants (11–15 mm) in combination with sinus floor elevation …

GP Schincaglia, DS Thoma, R Haas… - Journal of clinical …, 2015 - Wiley Online Library
Aim To compare, clinically and radiographically, short dental implants (6 mm) to long
implants (11–15 mm) placed with sinus grafting. Methods Participants with 5–7 mm of bone …

Four‐millimeter‐long posterior‐mandible implants: 5‐year outcomes of a prospective multicenter study

C Slotte, A Grønningsaeter, AM Halmøy… - … implant dentistry and …, 2015 - Wiley Online Library
Background There is lack of evidence on long‐term success of short dental implants in
reduced alveolar bone. Purpose In this prospective 5‐year study, survival and marginal …

Clinical study on survival rate of short implants placed in the posterior mandibular region: resonance frequency analysis

TP Queiroz, SC Aguiar, R Margonar… - Clinical oral implants …, 2015 - Wiley Online Library
Objective Short implants are increasingly used, but there is doubt about their performance
being similar to that of regular implants. The aim of this study was to compare the …

Three-dimensional finite element analysis of stress distribution in retention screws of different crown–implant ratios

SLD Moraes, EP Pellizzer, FR Verri… - Computer methods in …, 2015 - Taylor & Francis
The retaining screw of the implant-supported dental prosthesis is the weakest point of the
crown/implant system. Furthermore, crown height is another important factor that may …

Sandblasted and acid-etched implant surfaces with or without high surface free energy: experimental and clinical background

SK Roehling, B Meng, DL Cochran - Implant surfaces and their biological …, 2015 - Springer
The scientifically most investigated technique for creating a micro-rough surface topography
on dental implants is the sandblasting and acid-etching procedure, creating the well-known …

Survival rate of short, locking taper implants with a plateau design: a 5‐year retrospective study

KÖ Demiralp, N Akbulut, S Kursun… - BioMed Research …, 2015 - Wiley Online Library
Background. Short implants have become popular in the reconstruction of jaws, especially in
cases with limited bone height. Shorter implants, those with locking tapers and plateau root …

短种植体在骨量不足上颌后牙区的临床应用

刘林娟, 朱志军, 沈铭 - 口腔医学杂志, 2015 - stomatology.cn
目的评估短种植体在较低牙槽骨高度上颌后牙区使用的临床效果, 探讨其使用价值. 方法2009—
2011 年, 选取窦底骨高度为3~ 6 mm 患者26 例, 共植入37 枚短种植体, 随访25~ 48 …

Single restorations in the resorbed posterior mandible supported by 6‐mm implants: a 1‐year prospective case series study

FL Guljé, GM Raghoebar, A Vissink… - … Implant Dentistry and …, 2015 - Wiley Online Library
Purpose The aim of this prospective case series study was to assess the clinical
performance of single restorations in the posterior mandible supported by 6‐mm implants …