[HTML][HTML] Robust electrical impedance tomography for biological application: a mini review

Y Li, N Wang, LF Fan, PF Zhao, JH Li, L Huang… - Heliyon, 2023 - cell.com
Electrical impedance tomography (EIT) has been used by researchers across several areas
because of its low-cost and no-radiation properties. Researchers use complex conductivity …

Electrical impedance tomography for biomedical applications: Circuits and systems review

Y Wu, FF Hanzaee, D Jiang, RH Bayford… - IEEE Open Journal …, 2021 - ieeexplore.ieee.org
There has been considerable interest in electrical impedance tomography (EIT) to provide
low-cost, radiation-free, real-time and wearable means for physiological status monitoring …

A 13-Channel 1.53-mW 11.28-mm2 Electrical Impedance Tomography SoC Based on Frequency Division Multiplexing for Lung Physiological Imaging

B Liu, G Wang, Y Li, L Zeng, H Li, Y Gao… - IEEE transactions on …, 2019 - ieeexplore.ieee.org
An electrical impedance tomography (EIT) system based on frequency division multiplexing
(FDM) is proposed for real-time lung physiological imaging. The FDM technique allows the …

Structured design methodology to achieve a high SNR electrical impedance tomography

M Takhti, K Odame - IEEE transactions on biomedical circuits …, 2019 - ieeexplore.ieee.org
In this paper, we present a methodology for designing the main circuit building blocks of an
electrical impedance tomography (EIT) system. In particular, we derive equations that map …

A 1 MHz miniaturized electrical impedance tomography system for prostate imaging

A Rao, EK Murphy, RJ Halter… - IEEE transactions on …, 2020 - ieeexplore.ieee.org
An ASIC for a high frequency electrical impedance tomography (EIT) imaging system for
prostate cancer screening is presented. The ASIC enables a small form-factor architecture …

A 0.25-V fifth-order Butterworth low-pass filter based on fully differential difference transconductance amplifier architecture

PM Pinto, LHC Ferreira, GD Colletta, RAS Braga - Microelectronics Journal, 2019 - Elsevier
This paper presents a fifth-order Butterworth low-pass filter based on the fully differential
difference transconductance amplifier (FDDTA) building blocks. At first, the FDDTA has been …

Electrical impedance tomography: a review on hardware systems and circuits

W Li, H Shi, L Zhang, X Zhang, F Zhang… - Biomedical Physics & …, 2023 - iopscience.iop.org
Electrical impedance tomography (EIT) is a widely used functional imaging technology in the
field of biomedical engineering with the characteristics of non-radiation, high temporal …

DSP-based current source for electrical impedance tomography

GJ Saulnier, A Abdelwahab… - Physiological …, 2020 - iopscience.iop.org
Objective: EIT systems, particularly those that use a parallel, multiple source architecture,
require current sources with very high output impedance. To meet this requirement, sources …

A modified noise model of electrical impedance tomography system by considering colored noises

X Bai, J Sun, X Bai, S Sun, L Xu - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
Sufficient signal-to-noise ratio (SNR) is critical to guarantee the satisfactory performance of
an electrical impedance tomography (EIT) system. In this article, a thorough SNR analysis of …

A power adaptive, 1.22-pW/Hz, 10-MHz read-out front-end for bio-impedance measurement

M Takhti, K Odame - IEEE transactions on biomedical circuits …, 2019 - ieeexplore.ieee.org
This paper presents a read-out front-end application-specific integrated circuit (ASIC) for the
measurement of tissue impedances. The 10 mm 2 2-channel front-end ASIC is fabricated in …