Mueller matrix polarimetry using full Poincaré beams

JC Suárez-Bermejo, JCG de Sande… - Optics and Lasers in …, 2019 - Elsevier
Abstract Full Poincaré beams (FPBs) are proposed for polarimetric applications. Such
beams present all states of totally polarized light across their transverse section at once and …

Effects of typical liquid-crystal retarder errors on optimized Stokes polarimeters

I Montes-González, OG Rodríguez-Herrera… - Applied Optics, 2022 - opg.optica.org
Liquid crystal variable retarders (LCVRs) are often used in Stokes polarimeters as they allow
the measurement of different polarization components by applying an electric field that …

Optimized configuration for liquid crystal Stokes polarimeters in the presence of fast-axis orientation errors

I Montes-Gonzalez, M Avendaño-Alejo, NC Bruce… - Optics Letters, 2024 - opg.optica.org
We present an optimal configuration for Stokes polarimeters based on liquid crystal variable
retarders, with the minimum number of measurements. Due to the inherent variations of the …

Optimizing near-infrared polariscopic imaging for the living human eye

Q Jarecki, M Kupinski - Optics Express, 2024 - opg.optica.org
Hardware architectures and image interpretation can be simplified by partial polarimetry.
Mueller matrix (MM) polarimetry allows the investigation of partial polarimeter designs for a …

Simultaneous detection of polarization states and wavefront by an angular variant micro-retarder-lens array

T Wakayama, A Zama, Y Higuchi, Y Takahashi… - Optics …, 2024 - opg.optica.org
We have demonstrated simultaneous detection of the polarization states and wavefront of
light using a 7× 7 array of angular variant micro-retarder-lenses. Manipulating the angular …

Megahertz detection of spectroscopic polarization by a time-encoded supercontinuum vector beam

Y Inoue, J Ogawa, H Morita, K Sakaue, T Wakayama… - Applied Optics, 2024 - opg.optica.org
We demonstrated a 40-MHz detection of spectroscopic polarization by a supercontinuum
vector beam with a wavelength-dependent polarization state. To achieve the high-repetition …

Galway Liverpool Imaging Polarimeter–GLIP: design and prototype status

EGP O'Connor, ÉJ Harvey, N Devaney… - Ground-based and …, 2022 - spiedigitallibrary.org
The Galway Liverpool imaging polarimeter (GLIP) has been designed to perform
simultaneous linear and circular polarimetric measurements at sub-second cadence. The …

System Design, Noise Reduction, and Improved Dimension Reconstruction for High Performance Ellipsometry

B Jiang - 2022 - dspace.mit.edu
The advancement in nano-manufacturing and many other industries calls for high-
performance metrology and inspection methods. Nano-manufacturing has witnessed …

Simulation of the polarimetric response of microscopic semitransparent specimens immersed in water

OG Rodríguez-Herrera, NC Bruce… - … Remote Sensing IX, 2019 - spiedigitallibrary.org
We present numerical results of the simulation of the polarimetric response of microscopic,
semitransparent specimens immersed in water. The polarimetric response observed in our …