On the advance of SFCL: a comprehensive review

MR Barzegar‐Bafrooei, A Akbari Foroud… - IET Generation …, 2019 - Wiley Online Library
This study aims to provide a comprehensive review of various superconducting fault current
limiters (SFCLs) configurations. Regarding the applied technology, the different types of …

Comparison of inductive and resistive SFCL to robustness improvement of a VSC-HVDC system with wind plants against DC fault

L Chen, H Chen, Z Shu, G Zhang… - IEEE Transactions on …, 2016 - ieeexplore.ieee.org
For that wind plants are connected to an electric power grid through voltage source
converter-based high-voltage direct-current (VSC-HVDC) transmission, the improvement of …

Application of a SFCL for fault ride-through capability enhancement of DG in a microgrid system and relay protection coordination

H He, L Chen, T Yin, Z Cao, J Yang… - IEEE Transactions on …, 2016 - ieeexplore.ieee.org
Concerning that a short-circuit fault happens inside a microgrid system, parts of distributed
generation (DG) units may not meet the fault ride-through (FRT) requirements and will be …

Design and numerical analysis of the 15 kV class coreless inductive type SFCL

M Majka, J Kozak, S Kozak… - IEEE Transactions …, 2014 - ieeexplore.ieee.org
Superconducting fault current limiters (SFCLs) are the most attractive devices for the power
network, because limiters can be used to limit the short current in electrical network. This …

Analysis on magnetizing characteristics due to peak fault current limiting operation of a modified flux-lock-type SFCL with two magnetic paths

SC Ko, SH Lim - IEEE Transactions on Applied …, 2016 - ieeexplore.ieee.org
The advantage of the flux-lock-type superconducting fault current limiter (SFCL) is that the
operational current of the SFCL can be easily adjusted by the winding ratio and the winding …

Superconducting Surge Current Limiter

S Kozak - Energies, 2021 - mdpi.com
A superconducting fault current limiter (SFCL) for medium voltage networks cooled by a
cryocooler was designed, built and tested by the current author. For the construction of this …

Tests of the 15-kV class coreless superconducting fault current limiter

J Kozak, M Majka, T Blazejczyk… - IEEE Transactions on …, 2016 - ieeexplore.ieee.org
This paper presents the design and tests of a superconducting fault current limiter (SFCL) for
medium voltage as a device allowing for a more effective use of the existing power network …

Optimal allocation of flux-coupling-type SFCLs for a micro-grid with wind-PV hybrid generation and battery energy storage

L Chen, H Chen, J Yang, Y Tang… - 2016 Asian Conference …, 2016 - ieeexplore.ieee.org
Regarding the access of a micro-grid with multiple distributed generation (DG) units into the
power distribution network, superconducting fault current limiters (SFCLs) may be used to …

[PDF][PDF] Contribution for the Study of the Integration of Inductive Superconducting Fault Current Limiters in Electrical Distribution Grids, no

NMG Vilhena - 2020 - run.unl.pt
A wider adoption of distributed generation sources and an increased interconnection of
networks tend to increase the complexity of electric power grids, thus causing a surge in …

Three-winding coreless superconducting fault current limiter

M Majka, J Kozak - … in Modern Engineering and Medicine (PTZE …, 2019 - ieeexplore.ieee.org
Fault current is one of the basic threats to the elements of power systems. Fault current flow
can cause thermal and dynamic harmful effects on the operation of power equipment. An …