Microdosimetry for hadron therapy: A state of the art of detection technology

G Parisi, F Romano, G Schettino - Frontiers in Physics, 2022 - frontiersin.org
The interest in hadron therapy is growing fast thanks to the latest technological advances in
accelerators and delivery technologies, to the development of more and more efficient and …

[图书][B] Microdosimetry: experimental methods and applications

L Lindborg, A Waker - 2017 - taylorfrancis.com
Experimental microdosimetry deals with the measurement of charged particle energy
deposition in tissue equivalent volumes, ranging in size from nanometres to micrometres …

Recombination methods in the dosimetry of mixed radiation

N Golnik - 1996 - osti.gov
The work describes the state of art of recombination methods developed for the dosimetry of
mixed radiation fields. The existing theories of initial recombination of ions in gases is given …

Monte Carlo design study for thick gas electron multiplier-based multi-element microdosimetric detector

Z Anjomani, AR Hanu, WV Prestwich… - Nuclear Instruments and …, 2014 - Elsevier
To accomplish enhanced neutron dose response with high detection efficiency, a set of multi-
element microdosimetric detectors were designed using THick Gas Electron Multiplier …

[PDF][PDF] Recent results at the CERN-EC high energy reference field facility

C Birattari, M Höfert, T Rancati, M Silari, A Ferrari… - 1997 - cds.cern.ch
A reference facility for the intercomparison of active and passive detectors in high energy
neutron fields is available at CERN since 1993. A charged hadron beam (protons, pions) …

A time projection chamber with optical readout for charged particle track structure imaging

U Titt, A Breskin, R Chechik, V Dangendorf… - Nuclear Instruments and …, 1998 - Elsevier
We report about a nuclear track imaging system which is designed to study in detail the
ionization topology of charged particle tracks in a low-pressure gas. The detection method is …

Results of a large scale neutron spectrometry and dosimetry comparison exercise at the Cadarache moderator assembly

DJ Thomas, JL Chartier, H Klein… - Radiation protection …, 1997 - academic.oup.com
Abstract Eurados Working Group 7 recently organised a large-scale comparison of neutron
spectrometry and dosimetry measurements at the IPSN/SDOS laboratory of the CEA …

TEPC performance in the CANDU workplace

AJ Waker, K Szornel, J Nunes - Radiation protection dosimetry, 1997 - academic.oup.com
Tissue-equivalent proportional counters (TEPCs) have a number of features that make them
an attractive option for neutron monitoring around power reactors. These features are …

Measurement of lineal-energy distributions for neutrons of 8 keV to 65 MeV by using a tissue-equivalent proportional counter

T Nunomiya, E Kim, T Kurosawa… - Radiation protection …, 2002 - academic.oup.com
The lineal-energy spectra for monoenergetic and quasi-monoenergetic neutrons of 8 keV to
65 MeV were obtained using a tissue-equivalent proportional counter (TEPC). The …

International intercomparison of TEPC systems used for radiation protection

WG Alberts, E Dietz, S Guldbakke… - Radiation Protection …, 1989 - academic.oup.com
The irradiation conditions and procedures of an international intercomparison of tissue-
equivalent proportional counters used for radiation protection measurements are described …