Optimal coordination of double-inverse overcurrent relays for stable operation of DGs

TS Aghdam, HK Karegar… - IEEE Transactions on …, 2018 - ieeexplore.ieee.org
Due to the increasing penetration of distributed generations (DGs) in distribution networks,
the performance of protective relays is becoming more critical to maintain the stability of the …

An analytical method for analysis of large-disturbance stability of induction generators

AP Grilo, A de Assis Mota, LTM Mota… - IEEE Transactions on …, 2007 - ieeexplore.ieee.org
This paper presents an analytical method for analysis of large-disturbance stability of
squirrel-cage rotor induction generators. The proposed analytical method is based on the …

Transient stability study of distributed induction generators using an improved steady-state equivalent circuit method

N Zhou, P Wang, Q Wang… - IEEE Transactions on …, 2013 - ieeexplore.ieee.org
When a short-circuit fault occurs in a distribution network, speed and reactive power
consumption of an induction generator (IG) increase dramatically, which may cause system …

[PDF][PDF] Avaliação do comportamento de aerogeradores de velocidde fixa e variável integrados em redes elétricas fracas

MVA Nunes - 2003 - core.ac.uk
Esta tese apresenta propostas para o aumento da margem de estabilidade transitória pós-
falta de sistemas elétricos com grande integração de parques eólicos, que incluem o uso do …

Modelling analysis of transient stability simulation with high penetration of grid‐connected wind farms of DFIG type

L Shi, Z Xu, J Hao, Y Ni - … for Progress and Applications in Wind …, 2007 - Wiley Online Library
This paper shows a model of a doubly fed induction generator (DFIG) including a simplified
model of a wind turbine for the purpose of transient stability analysis of large‐scale power …

Application of bidirectional switches in the development of a voltage regulator for self-excited induction generators

FB Silva, FA da Silva Gonçalves, WE Vanço… - International Journal of …, 2018 - Elsevier
This study presents a voltage regulator that is specific to three-phase self-excited induction
generators (SEIG). The voltage regulator proposed in this paper uses a PID controller that …

含多感应发电机配电网的暂态稳定研究

周念成, 王强钢, 王鹏 - 中国电机工程学报, 2011 - epjournal.csee.org.cn
随着新能源的开发和利用, 小型和微型分布式发电机(distributed generator, DG)
开始接入配电网, 在配电网中可能会出现暂态稳定问题. 鼠笼式感应发电机(induction generator …

Transient analysis of a grid connected wind driven induction generator using a real-time simulation platform

M Ouhrouche - Renewable Energy, 2009 - Elsevier
Due to its simple construction, ruggedness and low cost, the induction generator driven by a
wind turbine and feeding power to the grid appears to be an attractive solution to the …

Three-phase-measurement-based load modeling technique using unbalanced fault data

S Han - IEEE Access, 2020 - ieeexplore.ieee.org
This study presents a load modeling technique using unsymmetrical fault data. Typically,
three-phase balanced fault data are prerequisite for load modeling; however, the existing …

[PDF][PDF] Tesis

A García - 2023 - ru.dgb.unam.mx
Los delitos sexuales contra menores en México nos atañen al ser un tema delicado por la
vulnerabilidad en el que las niñas, niños y adolescentes son abusados y las aristas en las …