Voltage transient management for Alternating Current trains with vacuum circuit breakers

T Moore, F Schmid, P Tricoli - IET Electrical Systems in …, 2022 - Wiley Online Library
Alternating current power supplies and rolling stock with 25 kV (50 or 60 Hz) and 15 kV (16.7
Hz) traction systems do not have the characteristics and behaviour of a typical three‐phase …

City-friendly smart network technologies and infrastructures: The Spanish experience

A Gómez-Expósito, A Arcos-Vargas… - Proceedings of the …, 2018 - ieeexplore.ieee.org
Efficient, resilient, and sustainable electricity delivery is a key cornerstone in increasingly
large and complex urban environments, where citizens expect to keep or rise their living …

Mitigating the Inrush Current of V/V Transformers Using Railway Conditioners

A Aghazadeh, E Hajipour, K Li, S Azizi - IEEE Access, 2024 - ieeexplore.ieee.org
Inrush current is high-magnitude current drawn by power transformers upon energization.
The severity of inrush current depends on factors such as the transformer's residual flux and …

Controlled switching of power transformer and shunt reactors for minimization of switching transients: a review

A Kumar, R Perveen, U Parikh - Journal of The Institution of Engineers …, 2021 - Springer
Switching transients arises due to random switching of power apparatus results in
degradation of thermal and dielectric health of equipment and system as a whole. Controlled …

Smart Switching in Single-Phase Grid-Connected Photovoltaic Power Systems for Inrush Current Elimination

GJ Martínez-Figueroa, S Bogarra, F Córcoles - Energies, 2023 - mdpi.com
Grid-connected photovoltaic (PV) power systems are one of the most promising
technologies to address growing energy demand and ecological challenges. This paper …

The effect of stator inter-turn short-circuit fault on dfig performance using fem

H Mellah, S Arslan, H Sahraoui… - … , Technology & Applied …, 2022 - papers.ssrn.com
Abstract Doubly-Fed Induction Generators (DFIG) are operated for wind energy production,
and as their capacity is increasing, their safety and reliability become more important …

Diagnosis of interturn faults of single-distribution transformers under controlled conditions during energization

D Guillen, JC Olivares-Galvan, R Escarela-Perez… - Measurement, 2019 - Elsevier
Turn-to-turn short circuits occur due to insulation damage in transformer windings and these
may potentially result in catastrophic faults affecting electric networks. In fact, transformer …

Impact of autotransformer inrush currents on differential protection operation

N Stipetic, B Filipovic-Grcic, M Perkovic - Electric Power Systems Research, 2023 - Elsevier
One of the main causes for incorrect operation of the transformer relay protection are inrush
currents. The transient inrush currents occur when energizing the unloaded transformer, and …

Improved flux-controlled VFCV strategy for eliminating and measuring the residual flux of three-phase transformers

S Zhang, C Yao, X Zhao, J Li, X Liu, L Yu… - … on Power Delivery, 2019 - ieeexplore.ieee.org
The residual flux (RF) in three-phase transformers can dramatically increase the inrush
current when the transformer is energized. The RF can also severely interfere with …

Application of probabilistic neural networks using high-frequency components' differential current for transformer protection schemes to discriminate between external …

P Chiradeja, C Pothisarn, N Phannil… - Applied Sciences, 2021 - mdpi.com
Internal and external faults in a power transformer are discriminated in this paper using an
algorithm based on a combination of a discrete wavelet transform (DWT) and a probabilistic …