Nondestructive testing for corrosion evaluation of metal under coating

R Wu, H Zhang, R Yang, W Chen, G Chen - Journal of Sensors, 2021 - Wiley Online Library
The use of steel has grown rapidly over the past decades. However, corrosion under coating
detection still presents challenges for nondestructive testing (NDT) techniques. One of such …

A review of microwave testing of glass fibre-reinforced polymer composites

Z Li, A Haigh, C Soutis, A Gibson… - … Testing and Evaluation, 2019 - Taylor & Francis
Microwave non-destructive testing has received extensive attention in recent years owing to
its advantages of non-contact inspection, no need for a coupling medium or sensors …

A Low-cost metamaterial sensor based on DS-CSRR for material characterization applications

W Shahzad, W Hu, Q Ali, H Raza, SM Abbas… - Sensors, 2022 - mdpi.com
This paper presents a metamaterial sensor using a double slit complementary square ring
resonator (DS-CSRR) that has been utilized for the measurement of dielectric materials …

Detection of semi-solid materials utilizing triple-rings CSRR microwave sensor

AJA Al-Gburi, NA Rahman, Z Zakaria, M Palandoken - Sensors, 2023 - mdpi.com
This article proposes the design, fabrication and measurement of a triple-rings
complementary split-ring resonator (CSRR) microwave sensor for semi-solid material …

Recent advances in nondestructive method and assessment of corrosion undercoating in carbon–steel pipelines

Z May, MK Alam, NA Nayan - Sensors, 2022 - mdpi.com
Carbon–steel pipelines have mostly been utilized in the oil and gas (OG) industry owing to
their strength and cost-effectiveness. However, the detection of corrosion under coating …

[HTML][HTML] High sensitivity and selectivity microwave biosensor using biofunctionalized differential resonant array implemented in LTCC for Escherichia coli detection

I Piekarz, J Sorocki, S Górska, H Bartsch, A Rydosz… - Measurement, 2023 - Elsevier
A novel method for label-free detection of Escherichia coli relying on microwave sensing is
proposed. A transmission-type differential resonator array biosensor covered with polyclonal …

Feasibility study of enhancing microwave brain imaging using metamaterials

E Razzicchia, I Sotiriou, H Cano-Garcia, E Kallos… - Sensors, 2019 - mdpi.com
We present an approach to enhance microwave brain imaging with an innovative
metamaterial (MM) planar design based on a cross-shaped split-ring resonator (SRR-CS) …

[HTML][HTML] Planar single and dual-resonant microwave biosensors for label-free bacteria detection

I Piekarz, S Górska, A Razim, J Sorocki… - Sensors and Actuators B …, 2022 - Elsevier
Label-free microwave resonator-type biosensors covered with polyclonal anti-Escherichia
coli antibodies are presented. The sensorsconstruction provides high sensitivity on the …

High-resolution probe design for measuring the dielectric properties of human tissues

X Wang, H Guo, C Zhou, J Bai - BioMedical Engineering OnLine, 2021 - Springer
Background In order to use the microwave to measure the dielectric constant of the human
body and improve the measurement resolution, a small near-field probe working at 915 MHz …

Array of planar resonator probes for rapid near-field microwave imaging

MA Abou-Khousa, A Haryono - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
Planar resonator probes have been successfully used for high-resolution near-field