UHF PD signal transmission in GIS: Effects of 90° bends and an L-shaped CIGRE step 1 test section

G Behrmann, S Franz, J Smajic… - … on Dielectrics and …, 2019 - ieeexplore.ieee.org
When applying radio-frequency (RF) techniques to measure and monitor partial discharges
(PD), the CIGREsensitivity verification'recommendation details a methodology for achieving …

Transient responses of overhead cables due to mode transition in high frequencies

H Xue, A Ametani, J Mahseredjian… - IEEE Transactions …, 2017 - ieeexplore.ieee.org
This paper investigates the effect of mode transition from low-frequency transverse
electromagnetic (earth-return wave) to high-frequency Sommerfeld-Goubau (surface wave) …

Very fast transients in a 500 kV gas-insulated substation

H Xue, A Ametani… - IEEE Transactions on …, 2018 - ieeexplore.ieee.org
This paper performs thorough investigations of very fast transients (VFTs) in a 500 kV gas-
insulated substation (GIS) by adopting complete earth-return impedance and admittance …

New methods of damping very fast transient overvoltages in gas-insulated switchgear

S Burow, U Straumann, W Köhler… - IEEE Transactions on …, 2014 - ieeexplore.ieee.org
Very fast transient overvoltages (VFTO) are a well-known phenomenon in gas-insulated
switchgear. They are mainly generated due to several pre-or restrikes during disconnector …

Influence of the switching speed of the disconnector on very fast transient overvoltage

S Yinbiao, H Bin, L Ji-Ming, C Weijiang… - IEEE transactions on …, 2013 - ieeexplore.ieee.org
During the switching of disconnectors in gas-insulated switchgear (GIS), repeated strikes
occur in the contact gap and lead to very fast transient overvoltage (VFTO). Severe VFTO …

Theoretical and experimental investigation of new innovative TMF–AMF contacts for high-current vacuum arc interruption

T Lamara, D Gentsch - IEEE Transactions on Plasma Science, 2013 - ieeexplore.ieee.org
This paper consists of investigating the vacuum arc behavior during the high-current
interruption process with a new innovative coaxial double-contact system. The structure of …

Electromagnetic disturbances in gas-insulated substations and VFT calculations

A Ametani, H Xue, M Natsui, J Mahseredjian - Electric Power Systems …, 2018 - Elsevier
This paper is focused on the oscillating frequencies of very-fast transients (VFTs) generated
by disconnector and circuit breaker operations in gas-insulated substations (GISs) related to …

Signal delay effects of solid dielectrics on time-of-flight measurements in GIS

G Behrmann, K Wyss, J Weiss… - IEEE transactions on …, 2016 - ieeexplore.ieee.org
So-calledtime-of-flight'(TOF) measurements have been employed for locating PD sources
within GIS for over 20 years. Portable digital sampling oscilloscopes have now become …

Full-Maxwell simulations of very fast transients in GIS: Case study to compare 3-d and 2-d-axisymmetric models of 1100 kv test setup

M Szewczyk, K Kutorasiński, M Wroński… - … on Power Delivery, 2016 - ieeexplore.ieee.org
Development and type testing of gas-insulated switchgear (GIS) disconnectors are
supported with the simulation-based analyses of very fast transients (VFTs) that are …

3D full maxwell research for effect of initial electromagnetic field on very fast transient overvoltage in GIS

B Lu, Y Shi, X Lin, X Bian - IEEE Transactions on Dielectrics …, 2016 - ieeexplore.ieee.org
Very fast transient overvoltage (VFTO) generated by operating disconnect in gas insulated
substations has great concern in high voltage rated substation. Because many effecting …