End-to-end tests using alanine dosimetry in scanned proton beams

A Carlino, C Gouldstone, G Kragl… - Physics in Medicine …, 2018 - iopscience.iop.org
End-to-end tests using alanine dosimetry in scanned proton beams - IOPscience Skip to
content IOP Science home Accessibility Help Search Journals Journals list Browse more than …

[HTML][HTML] Empirical quenching correction in radiochromic silicone-based three-dimensional dosimetry of spot-scanning proton therapy

LB Valdetaro, EM Høye, PS Skyt, JBB Petersen… - Physics and Imaging in …, 2021 - Elsevier
Background and purpose Three-dimensional dosimetry of proton therapy (PT) with chemical
dosimeters is challenged by signal quenching, which is a lower dose-response in regions …

High-accuracy fluence determination in ion beams using fluorescent nuclear track detectors

JM Osinga, MS Akselrod, R Herrmann, V Hable… - Radiation …, 2013 - Elsevier
We present an approach to use Al 2 O 3: C, Mg-based fluorescent nuclear track detectors
(FNTDs) and confocal laser scanning microscopy as a semiautomatic tool for fluence …

Evaluation of the relative thermoluminescence efficiency of LiF: Mg, Ti and LiF: Mg, Cu, P TL detectors to low-energy heavy ions

W Gieszczyk, P Bilski, P Olko, R Herrmann… - Radiation …, 2013 - Elsevier
The most popular types of LiF-based thermoluminescent (TL) detectors, LiF: Mg, Ti (MTS-N)
and LiF: Mg, Cu, P (MCP-N), have been investigated, with respect to their dose (fluence) …

Cross calibration of alanine for scanned proton beams

H Palmans, A Carlino, C Gouldstone, P Sharpe - 2018 - eprintspublications.npl.co.uk
Alanine is a suitable dosimeter for absolute dosimetry, dose verification, end-to-end
dosimetry and dosimetric audit of clinical proton beams. For establishing traceability to …

[PDF][PDF] Fluorescent nuclear track detectors: high-accuracy fluence determination in ion beams

JM Osinga - Master's thesis, Martin Luther University Halle …, 2012 - Citeseer
There have been implications in literature that the accuracy of commonly used CR-39 plastic
nuclear track detectors (PNTDs) might be hampered by incomplete detection of single …

Detectors, relative dosimetry, and microdosimetry

H Palmans - Proton Therapy Physics, 2020 - api.taylorfrancis.com
9.1 INTRODUCTION—DETECTOR REQUIREMENTS FOR RELATIVE DOSIMETRY AND
MICRODOSIMETRY Relative dosimetry concerns the measurement of relative distributions …

[PDF][PDF] Modelos de traços aplicados ao cálculo da eficiência da produção de radicais livres produzidos por partículas carregadas em água

BM Magiore - 2022 - repositorio.unesp.br
Foi utilizada a formulação dielétrica na aproximação MELF-GOS para o cálculo de largura
de traços produzidos por prótons e partículas alfa em alvos de água líquida. Os alcances …