A Comprehensive Review on STATCOM: Paradigm of Modelling, Control, Stability, Optimal Location, Integration, Application, and Installation

S Sharma, S Gupta, M Zuhaib, V Bhuria, H Malik… - IEEE …, 2023 - ieeexplore.ieee.org
The Static synchronous compensator (STATCOM) is a renowned FACTS (flexible alternating
current transmission system) device used in power grids to cope with protean conditions …

Selective harmonic elimination technique with control of capacitive DC-link voltages in an asymmetric cascaded H-bridge inverter for STATCOM application

R Sajadi, H Iman-Eini… - IEEE Transactions …, 2018 - ieeexplore.ieee.org
In this paper, the selective harmonic elimination (SHE) technique is introduced for a
cascaded H-bridge-based static VAR compensator (CHB-STATCOM) with unequal …

Space vector pulsewidth modulation strategy for multilevel cascaded H-bridge inverter with DC-link voltage balancing ability

A Lewicki, IC Odeh, M Morawiec - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
Space vector pulsewidth modulation (SVPWM) algorithms for cascaded H-bridge multilevel
(CHB ML) inverter usually provide the possibility of using several combinations of active …

Inter‐module state‐of‐charge balancing and fault‐tolerant operation of cascaded H‐bridge converter using multi‐dimensional modulation for electric vehicle …

K Kandasamy, M Vilathgamuwa… - IET Power …, 2015 - Wiley Online Library
This study presents a method for module‐level state‐of‐charge (SOC) balancing and fault‐
tolerant operation of the cascaded H‐bridge (CHB) converter‐based battery energy storage …

State feedback control strategy and voltage balancing scheme for a transformer‐less STATic synchronous COMpensator based on cascaded H‐bridge converter

Y Neyshabouri, H Iman‐Eini… - IET Power …, 2015 - Wiley Online Library
In this study, a transformer‐less STATic synchronous COMpensator (STATCOM) based on
cascaded H‐bridge (CHB) multilevel converter with floating DC links is presented. This study …

Adaptive hysteresis and fuzzy logic controlled‐based shunt active power filter resistant to shoot‐through phenomenon

AK Panda, R Patel - IET Power Electronics, 2015 - Wiley Online Library
This study proposes a novel adaptive hysteresis and fuzzy logic controlled based 3‐phase 4‐
wire full bridge interleaved buck active power filter (FB IB‐APF) which eliminates current …

Characterization and performance evaluation of the state-of-the-art 3.3 kV 30 A full-SiC MOSFETs

A Marzoughi, R Burgos… - IEEE Transactions on …, 2018 - ieeexplore.ieee.org
With their intrinsic superiorities such as high breakdown electric field and high thermal
conductivity, the silicon carbide (SiC) mosfets are replacing traditional Si insulated gate …

Fault-tolerant operation of cascaded H-Bridge inverters using one redundant cell

P Moamaei, H Mahmoudi… - 2015 IEEE Power and …, 2015 - ieeexplore.ieee.org
This paper presents a fault-tolerant technique for multilevel Cascaded H-Bridge (CHB)
inverters. A faulty power switch in high power converters can lead to expensive downtime …

Reliable transformerless battery energy storage systems based on cascade dual‐boost/buck converters

C Liu, J Kan, Y Zhi, W Li, J Sun, G Cai… - IET Power …, 2015 - Wiley Online Library
In this study, the cascade dual‐boost/buck half‐bridge and full‐bridge bidirectional ac–dc
converters are proposed for grid‐tie transformerless battery energy storage systems …

Switching frequency variation based on current ripple analysis of a 3‐L PMSM drive system considering neutral point balance

X Zhao, X Wang, S Liu, C Gu, S Zhao… - IET Power …, 2020 - Wiley Online Library
The output current ripple of the three‐level (3‐L) inverter is important to the performance of
the 3‐L permanent magnetic synchronous motor (PMSM) drive system, but the neutral point …