Applications of nonlinearity in passive vibration control: a review

PS Balaji, K Karthik SelvaKumar - Journal of Vibration Engineering & …, 2021 - Springer
Background Vibration present on various levels in many engineering fields and hence
vibration mitigation has become a subject of intense study. The nonlinear vibration isolation …

Modelling of Hysteresis in Vibration Control Systems by means of the Bouc‐Wen Model

CM Chang, S Strano, M Terzo - Shock and Vibration, 2016 - Wiley Online Library
The review presents developments concerning the modelling of vibration control systems
with hysteresis. In particular, the review focuses on applications of the Bouc‐Wen model that …

Nonlinear analysis of vibration attenuation of ring-spring-resonator based meta-isolation system

D Shi, H Chen, H He, Y Li, X An, F Jin, H Fan - Engineering Structures, 2023 - Elsevier
Abstract Ring-spring-resonator (RSR) based nonlinear meta-isolation system (RSR-M) was
proposed and its vibration attenuation characteristic was investigated experimentally and …

An experimental investigation into the shock response of a compact wire rope isolator in its axial direction

DF Ledezma-Ramírez, PE Tapia-González… - Engineering …, 2022 - Elsevier
The use of wire rope isolators (WRIs) for vibration and shock response attenuation is
extensive, as these isolators offer a high level of energy storage due to deflection in different …

A magneto-rheological elastomer vibration isolator for lightweight structures

R Brancati, G Di Massa, S Pagano, S Santini - Meccanica, 2019 - Springer
Abstract Magneto-rheological elastomers (MRE), consisting of elastomeric matrix containing
ferromagnetic particles, are a kind of smart material, whose mechanical properties are …

An analytical study on the static vertical stiffness of wire rope isolators

PS Balaji, L Moussa, ME Rahman, LH Ho - Journal of Mechanical Science …, 2016 - Springer
The vibrations caused by earthquake ground motions or the operations of heavy
machineries can affect the functionality of equipment and cause damages to the hosting …

Experimental Investigations on the Dynamic Behaviour of O‐Type Wire‐Cable Vibration Isolators

HX Wang, XS Gong, F Pan, XJ Dang - Shock and Vibration, 2015 - Wiley Online Library
A series of periodic loading experiments were carried out on the O‐type wire‐cable vibration
isolators. The isolators were loaded under shear, roll, and tension‐compression loadings …

Effectiveness study of wire mesh vibration damper for sensitive equipment protection from seismic events

F Mezghani, AF del Rincón, PG Fernandez… - … Systems and Signal …, 2022 - Elsevier
Abstract Wire Mesh Vibration Damper (WMVD) is proposed for the protection of vibration-
sensitive equipment, such as Information Technology (IT) equipment, from seismic events …

Analysis of vibration isolation performance of parallel air spring system for precision equipment transportation

D Qu, X Liu, G Liu, Y Bai, T He - Measurement and Control, 2019 - journals.sagepub.com
Precision equipment is usually accompanied with vibrations during road or railway
transportation. Sometimes the vibration exceeds the given limit, leading to the damage of the …

Real‐time hybrid simulations vs shaking table tests: case study of a fibre‐reinforced bearings isolated building under seismic loading

A Calabrese, S Strano, M Terzo - Structural Control and Health …, 2015 - Wiley Online Library
In this paper, real‐time hybrid simulations (RTHSs) and shaking table tests (STTs) are
described to assess the feasibility of using recycled rubber fibre‐reinforced bearings (FRBs) …