[HTML][HTML] SIAMOC position paper on gait analysis in clinical practice: General requirements, methods and appropriateness. Results of an Italian consensus conference

MG Benedetti, E Beghi, A De Tanti, A Cappozzo… - Gait & posture, 2017 - Elsevier
Gait analysis is recognized as a useful assessment tool in the field of human movement
research. However, doubts remain on its real effectiveness as a clinical tool, ie on its …

Methodological factors affecting joint moments estimation in clinical gait analysis: a systematic review

V Camomilla, A Cereatti, AG Cutti, S Fantozzi… - Biomedical engineering …, 2017 - Springer
Quantitative gait analysis can provide a description of joint kinematics and dynamics, and it
is recognized as a clinically useful tool for functional assessment, diagnosis and intervention …

[HTML][HTML] A public data set of human balance evaluations

DA Santos, M Duarte - PeerJ, 2016 - peerj.com
The goal of this study was to create a public data set with results of qualitative and
quantitative evaluations related to human balance. Subject's balance was evaluated by …

[PDF][PDF] Clinical stabilometry standardization: Feet position in the static stabilometric assessment of postural stability

F Scoppa, M Gallamini, G Belloni, G Messina - Acta Med. Mediterr, 2017 - researchgate.net
Introduction: We address the topic of feet position during the quiet upright stance balance
test over a force platform. Such position is widely discussed and three among the most …

Measurement of the Impact Loads to Reduce Injuries in Acrobatic Gymnasts: Designing a Dedicated Platform

MF Paulino, BB Gomes, AL Ramalho, AM Amaro - Applied Sciences, 2024 - mdpi.com
Background: The main objective of this study was the development of a specific load
platform that would meet the needs of gymnasts and acrobatic coaches. This new platform …

[PDF][PDF] Design and construction of a 3D force plate prototype for developing an instrumented swimming start block

L Mourão, K De Jesus, N Viriato… - Journal of Biomedical …, 2016 - cifi2d.fade.up.pt
Force plates have been used in human movement analysis to measure ground reaction
forces, centre of pressure (COP) and derived kinetic quantities. In competitive swimming …

Designing a Multiaxial Extensometric Force Platform: A Manufacturing Experience

JR Beingolea, HA Rodrigues, M Zegarra… - Electronics, 2021 - mdpi.com
Studies that lead to the development of more accessible and low-cost electronic
technologies and devices for biomechanical and biomedical analysis applications are …

Agreement of three posturographic force plates in the assessment of postural stability

P Matłosz, J Wyszyńska, J Podgórska-Bednarz… - International Journal of …, 2020 - mdpi.com
This study was designed to assess how the results obtained for three different
posturographic platforms agreed with each other in an assessment of static postural stability …

Invariant density analysis: Modeling and analysis of the postural control system using markov chains

P Hur, KA Shorter, PG Mehta… - IEEE Transactions on …, 2012 - ieeexplore.ieee.org
In this paper, a novel analysis technique, invariant density analysis (IDA), is introduced. IDA
quantifies steady-state behavior of the postural control system using center of pressure …

[PDF][PDF] Metrological performance of instruments used in clinical evaluation of balance

FR Carrick, A Hankir, R Zaman, C HG Wright - Psychiatria Danubina, 2019 - hrcak.srce.hr
METROLOGICAL PERFORMANCE OF INSTRUMENTS USED IN CLINICAL EVALUATION OF
BALANCE Page 1 S324 Psychiatria Danubina, 2019; Vol. 31, Suppl. 3, pp 324-330 Conference …