Ballistocardiography and seismocardiography: A review of recent advances

OT Inan, PF Migeotte, KS Park… - IEEE journal of …, 2014 - ieeexplore.ieee.org
In the past decade, there has been a resurgence in the field of unobtrusive
cardiomechanical assessment, through advancing methods for measuring and interpreting …

Ballistocardiogram signal processing: A review

I Sadek, J Biswas, B Abdulrazak - Health information science and systems, 2019 - Springer
Across the world, healthcare costs are projected to continue to increase, and the pressure
on the healthcare system is only going to grow in intensity as the rate of growth of elderly …

A smart health monitoring chair for nonintrusive measurement of biological signals

HJ Baek, GS Chung, KK Kim… - IEEE transactions on …, 2011 - ieeexplore.ieee.org
We developed nonintrusive methods for simultaneous electrocardiogram,
photoplethysmogram, and ballistocardiogram measurements that do not require direct …

Systems and methods for monitoring the circulatory system

RM Wiard, LB Giovangrandi, GT Kovacs - US Patent 9,011,346, 2015 - Google Patents
In accordance with embodiments of the present disclosure, a ballistocardiogram (BCG)
sensor is used to detect heart and vascular characteristics of a user, and provide a BCG …

A dynamic bayesian multi-channel fusion scheme for heart rate monitoring with ballistocardiograph signals in free-living environments

J Qi, R Cai, Q Liu, W Wang, J Ma… - IEEE Journal of Selected …, 2024 - ieeexplore.ieee.org
Ballistocardiograph (BCG) stands out as a noncontact technology for heart monitoring,
offering a wealth of cardiovascular parameter information. Its applications have …

Vital sign monitoring in car seats based on electrocardiography, ballistocardiography and seismocardiography: A review

M Sidikova, R Martinek, A Kawala-Sterniuk, M Ladrova… - Sensors, 2020 - mdpi.com
This paper focuses on a thorough summary of vital function measuring methods in vehicles.
The focus of this paper is to summarize and compare already existing methods integrated …

Non-constrained monitoring of systolic blood pressure on a weighing scale

JH Shin, KM Lee, KS Park - Physiological measurement, 2009 - iopscience.iop.org
In this study, we developed a novel technique for estimating non-constrained and cuffless
blood pressure (BP) that was based on electrocardiogram (ECG) and ballistocardiogram …

Improvement of ride quality for patient lying in ambulance with a new hydro-pneumatic suspension

B Tan, Y Wu, N Zhang, B Zhang… - Advances in …, 2019 - journals.sagepub.com
Instability caused by emergency braking and steering during ambulance operation would
easily lead to a sharp rise of blood pressure in patient's head, which would further cause a …

Wearable sensors incorporating compensatory reserve measurement for advancing physiological monitoring in critically injured trauma patients

VA Convertino, SG Schauer, EK Weitzel, S Cardin… - Sensors, 2020 - mdpi.com
Vital signs historically served as the primary method to triage patients and resources for
trauma and emergency care, but have failed to provide clinically-meaningful predictive …

Systems and methods for monitoring heart function

OT Inan, M Etemadi, LB Giovangrandi… - US Patent …, 2014 - Google Patents
Characteristics of a user's heart are detected. In accordance with an example embodiment, a
ballistocardiogram (BCG) sensor is used to detect heart characteristics of a user, and …