Theoretical study of a simplified implementation model of a dual-energy technique for computed tomography

S Osipov, S Chakhlov, A Batranin, O Osipov… - NDT & E …, 2018 - Elsevier
The article describes a theoretical study of the simplified implementation of dual energy
technique (DET) for computed tomography (CT). The implementation is based on the X-ray …

Parameter identification method for dual-energy X-ray imaging

S Osipov, E Libin, S Chakhlov, O Osipov, A Shtein - NDT & E International, 2015 - Elsevier
The paper presents a method for parameter identification of dual-energy X-ray imaging. This
method is based on pre-calculated or experimentally obtained dependencies between the …

The mathematical model of image, generated by scanning digital radiography system

VA Udod, SP Osipov, Y Wang - IOP Conference Series: Materials …, 2017 - iopscience.iop.org
The mathematical model of image, generated by scanning digital radiography system is
present. This model takes into account the X-ray energy spectrum transformation of the test …

Simulation modeling in digital radiography with allowance for spatial outlines of test objects

SP Osipov, IG Yadrenkin, SV Chakhlov… - Russian Journal of …, 2020 - Springer
Algorithms are proposed for modeling the spatial outlines of test objects and forming their
images in digital radiography systems. The algorithms provide the basis for simulation …

[PDF][PDF] Physical and technical restrictions of materials recognition by the dual high energy X-ray imaging

SP Osipov, SV Chakhlov, OS Osipov, S Li… - … Journal of Applied …, 2017 - researchgate.net
The paper presents physical and technical restrictions of the materials recognition of objects
and their fragments using the dual energy method. It is shown that the recognition …

About accuracy of the discrimination parameter estimation for the dual high-energy method

SP Osipov, SV Chakhlov, OS Osipov… - IOP Conference …, 2015 - iopscience.iop.org
A set of the mathematical formulas to estimate the accuracy of discrimination parameters for
two implementations of the dual high energy method-by the effective atomic number and by …

Numerical modeling of radiographic images as the basis for correctly designing digital radiography systems of large-sized objects

SP Osipov, SV Chakhlov, DU Kairalapov… - Russian Journal of …, 2019 - Springer
A mathematical model has been developed for digital radiographic imaging of large-sized
objects. The model takes account of scanning time, the parameters of source and recorder of …

Identification of the substance of a test object using the dual-energy method

VA Klimenov, SP Osipov, AK Temnik - Russian journal of nondestructive …, 2013 - Springer
The contribution of different components to the total error in measuring the effective atomic
number of the substance of a homogeneous test object is assessed using the dual-energy …

Estimation of parameters of digital radiography systems

SP Osipov, GL Zhang, SV Chakhlov… - … on Nuclear Science, 2018 - ieeexplore.ieee.org
Based on the test object and the given data from the detectors, a set of formulas connecting
the characteristics of digital radiography (DR) systems with the parameters of the X-ray …

Selecting parameters of detectors when recognizing materials based on the separation of soft and hard x-ray components

SP Osipov, EY Usachev, SV Chakhlov… - Russian Journal of …, 2018 - Springer
An approach to choosing the materials and thicknesses of detectors and an intermediate
filter is considered in a material recognition method based on single X-raying of a test object …