[HTML][HTML] Approach to hypoglycemia in infants and children

K Gandhi - Translational pediatrics, 2017 - ncbi.nlm.nih.gov
Hypoglycemia is a heterogeneous disorder with many different possible etiologies, including
hyperinsulinism, glycogen storage disorders, fatty acid disorders, hormonal deficiencies …

HbA1c and biomarkers of diabetes mellitus in Clinical Chemistry and Laboratory Medicine: ten years after

P Gillery - Clinical Chemistry and Laboratory Medicine (CCLM), 2023 - degruyter.com
Since its discovery in the late 1960s, HbA1c has proven to be a major biomarker of diabetes
mellitus survey and diagnosis. Other biomarkers have also been described using classical …

Clot activators and anticoagulant additives for blood collection. A critical review on behalf of COLABIOCLI WG-PRE-LATAM

G Lima-Oliveira, LM Brennan-Bourdon… - Critical Reviews in …, 2021 - Taylor & Francis
In the clinical laboratory, knowledge of and the correct use of clot activators and
anticoagulant additives are critical to preserve and maintain samples in optimal conditions …

Effect of collection tube type on glucose stability in whole blood

J Jung, E Garnett, K Rector, P Jariwala… - Annals of Clinical & …, 2020 - Assoc Clin Scientists
Precise measurement of plasma glucose is essential in evaluation of diabetes. In vitro
decreases in glucose concentration due to glycolysis may lead to missed diabetes …

[HTML][HTML] Deviating glucose results in an international dual-center study. A root cause investigation

J Cadamuro, P Bergsten, K Mörwald, A Forslund… - Biochemia …, 2022 - hrcak.srce.hr
Sažetak During a dual-center study on obese and normal weight children and adolescents,
focusing on glucose metabolism, we observed a marked difference in glucose results (N …

Clinical impact of citrate-containing tubes on the detection of glucose abnormalities by the oral glucose tolerance test

G Bonetti, D Giavarina, M Carta - Diagnosis, 2019 - degruyter.com
Background Plasma glucose levels provide the cornerstone of diabetes evaluation, and so it
is crucial that clinical laboratories provide accurate and reliable plasma glucose results. To …

Five days serum glucose stability at room-temperature in centrifuged fast-clotting serum tubes and the comparability with glucose in heparin-plasma and plasma …

H Bakkebø, KL Haaland, KS Hoff… - … Journal of Clinical and …, 2024 - Taylor & Francis
Glucose measurement plays a central role in the diagnosis of gestational diabetes mellitus
(GDM). Because of earlier reports of overestimation of glucose in the widely used tubes …

[HTML][HTML] Glucose inhibitor tubes in Croatian laboratories: are we doing well?

A Vrtarić, N Nikolac Gabaj, I Ćelap - Biochemia Medica, 2024 - hrcak.srce.hr
Materials and methodsSurvey was performed in form of questionnaire. Questionnaire was
sent to all Croatian laboratories (N= 204) in electronic form using SurveyMonkey cloud …

Impact of citrated blood collection tubes on red cell morphology: implications for the measurement of plasma glucose

H Lunt, HF Heenan, P Edwards… - Clinical Chemistry and …, 2018 - degruyter.com
The glucose stabilising effect of citrated blood collection tubes is well known. Lowering the
pH in blood collection tubes below 7.0 'freezes' several enzymes within the Emden …

Relative Wirksamkeit verschiedener Vorgehensweisen zur Hemmung der in-vitro Glykolyse

MM Fischer - 2022 - epub.ub.uni-greifswald.de
Die Stoffwechselerkrankung Diabetes mellitus lässt sich auf eine Insulinresistenz oder einen
Insulinmangel zurückführen. Da die Prävalenz des Diabetes mellitus in den letzten …