2021 ESC/EACTS Guidelines for the management of valvular heart disease: developed by the Task Force for the management of valvular heart disease of the …

A Vahanian, F Beyersdorf, F Praz… - European heart …, 2022 - academic.oup.com
Health professionals are encouraged to take the ESC/EACTS Guidelines fully into account
when exercising their clinical judgment, as well as in the determination and the …

2021 ESC/EACTS Guidelines for the management of valvular heart disease: developed by the Task Force for the management of valvular heart disease of the …

F Beyersdorf, A Vahanian, M Milojevic… - European journal of …, 2021 - academic.oup.com
731 F. Beyersdorf and A. Vahanian et al./European Journal of Cardio-Thoracic Surgery
guidelines, which is freely available via the ESC and EACTS website and hosted on the EHJ …

Prosthesis–patient mismatch in patients undergoing transcatheter aortic valve replacement: from the STS/ACC TVT registry

HC Herrmann, SA Daneshvar, GC Fonarow… - Journal of the American …, 2018 - jacc.org
Background: Prosthesis–patient mismatch (PPM) after surgical aortic valve replacement
(AVR) for aortic stenosis is generally associated with worse outcomes. Transcatheter AVR …

Valve-in-valve transcatheter aortic valve replacement versus redo surgical aortic valve replacement: an updated meta-analysis

MPBO Sá, J Van den Eynde, M Simonato… - Cardiovascular …, 2021 - jacc.org
Objectives The aim of this study was to evaluate early results of valve-in-valve (ViV)
transcatheter aortic valve replacement (TAVR) versus redo surgical aortic valve replacement …

Prosthesis-patient mismatch after aortic valve replacement in the PARTNER 2 trial and registry

J Ternacle, P Pibarot, HC Herrmann, S Kodali… - Cardiovascular …, 2021 - jacc.org
Objectives This study aimed to compare incidence and impact of measured prosthesis-
patient mismatch (PPMM) versus predicted PPM (PPMP) after surgical aortic valve …

Imaging for predicting and assessing prosthesis-patient mismatch after aortic valve replacement

P Pibarot, J Magne, J Leipsic, N Côté, P Blanke… - JACC: Cardiovascular …, 2019 - jacc.org
Prosthesis-patient mismatch (PPM) occurs when the effective orifice area (EOA) of the
prosthetic valve is too small in relation to a patient's body size, thus resulting in high residual …

Effect of prosthesis-patient mismatch on long-term clinical outcomes after bioprosthetic aortic valve replacement

M Dismorr, N Glaser, A Franco-Cereceda… - Journal of the American …, 2023 - jacc.org
Background Prosthesis-patient mismatch (PPM) is common following surgical aortic valve
replacement (SAVR). Objectives The purpose of this study was to quantify the impact of PPM …

Cardiac surgery in women in the current era: what are the gaps in care?

L Cho, MR Kibbe, F Bakaeen, NR Aggarwal… - Circulation, 2021 - Am Heart Assoc
Cardiovascular disease remains the leading cause of morbidity and mortality for women in
United States and worldwide. One in 3 women dies from cardiovascular disease, and 45 …

Aortic stenosis and small aortic annulus: clinical challenges and current therapeutic alternatives

AB Freitas-Ferraz, G Tirado-Conte, F Dagenais… - Circulation, 2019 - Am Heart Assoc
The presence of a small aortic annulus poses a considerable challenge in the management
of patients with severe aortic stenosis, especially in elderly women, where it is a very …

Prosthesis-patient mismatch following transcatheter aortic valve replacement with supra-annular and intra-annular prostheses

T Okuno, F Khan, M Asami, F Praz, D Heg… - JACC: Cardiovascular …, 2019 - jacc.org
Objectives: This study sought to compare the frequency of prosthesis-patient mismatch
(PPM) with self-expandable valves (SEV) to balloon-expandable valves (BEV). Background …