A Digital Twin Based Health Status Monitoring Method for Single-Phase PWM Rectifiers

S Zhang, W Song, H Cao, T Tang… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
A digital simulation and health monitoring method for single-phase two-level pulsewidth
modulation (PWM) rectifiers based on digital twin technology is proposed in this article. First …

Estimation of equivalent inductance and resistance for adaptive control of three-phase PWM rectifiers

A Bechouche, DO Abdeslam… - IECON 2016-42nd …, 2016 - ieeexplore.ieee.org
In this paper, an adaptive voltage-oriented control (VOC) for three-phase grid-connected
pulse-width modulation (PWM) rectifier is developed. As the control loop behavior is affected …

Improved Sensorless DPC With Constant Switching Frequency for Non-Ideal Grid

A Rath, S Gopalakrishna… - IEEE Transactions on …, 2024 - ieeexplore.ieee.org
In non-ideal grids, DPC methods involving ac voltage sensors have high accuracy, proving
their tremendous adaptability. However, the sensorless methods continue to struggle in the …

AC voltage sensorless control of three-phase PWM rectifiers

A Bechouche, DO Abdeslam… - 2015 3rd International …, 2015 - ieeexplore.ieee.org
Three-phase pulse-width modulation (PWM) rectifiers are being increasingly used as high
performance grid interface in power systems like distributed and renewable energy …

Online estimation of passive elements in a double conversion UPS system with no additional sensors

TJL Oliveira, TMC Baptista, LMA Caseiro… - 2021 Telecoms …, 2021 - ieeexplore.ieee.org
Uninterruptible Power Supplies (UPS) represent the main technology used to supply a wide
range of critical applications in which information, communication and technology (ICT) …

A stable adaptive gradient descent harmonic-disturbance rejection for improving phase-tracking accuracy

TNC Tran, HX Nguyen, JW Park, JW Jeon - IEEE Access, 2020 - ieeexplore.ieee.org
This paper proposes a stable adaptive gradient descent for harmonic-disturbance rejection
as a tool for grid-power signal processing, magnetic rotary encoders, and permanent …

A Rapid Output Disturbance Suppression Method for AFE Rectifier Unit Based on the New Load Current Feedforward

X Yao, X Hu, H Ma, J Wang - 2018 37th Chinese Control …, 2018 - ieeexplore.ieee.org
In order to reduce the excessive fluctuation of the DC-link voltage on the AFE rectifier unit
output side caused by frequent load changes during ship crane operation, this paper …

Diagnóstico de avarias em fontes de energia ininterrupta ligadas em paralelo

TMC Baptista - 2021 - estudogeral.uc.pt
A maioria dos sistemas de energia atuais apresentam uma eficiência e performance de
nível elevado, fruto da evolução de processos de conversão de energia e aplicações …

[PDF][PDF] European Journal of Electrical Engineering

M Latroch, M Khiat, D Rahiel - European Journal of Electrical …, 2019 - scholar.archive.org
Accepted: 20 August 2019 Protection relay is an important part of any electric power system.
Recently, many neural networks have been applied to protective relaying. This paper …

[引用][C] An IDMT Overcurrent Protective Relay Based on ADALINE An IDMT Overcurrent Protective Relay Based on ADALINE

M Latroch, M Khiat, D Rahiel