A copolymer-in-oil tissue-mimicking material with tuneable acoustic and optical characteristics for photoacoustic imaging phantoms

L Hacker, J Joseph, AM Ivory, MO Saed… - … on Medical Imaging, 2021 - ieeexplore.ieee.org
Photoacoustic imaging (PAI) standardisation demands a stable, highly reproducible physical
phantom to enable routine quality control and robust performance evaluation. To address …

Patient-specific neurosurgical phantom: assessment of visual quality, accuracy, and scaling effects

FW Grillo, VH Souza, RH Matsuda, C Rondinoni… - 3D Printing in …, 2018 - Springer
Background Training in medical education depends on the availability of standardized
materials that can reliably mimic the human anatomy and physiology. One alternative to …

Glycerol-in-SEBS gel as a material to manufacture stable wall-less vascular phantom for ultrasound and photoacoustic imaging

LC Cabrelli, JH Uliana, LB da Cruz Junior… - Biomedical Physics …, 2021 - iopscience.iop.org
Abstract Styrene-ethylene/butylene-styrene (SEBS) copolymer-in-mineral oil gel is an
appropriate tissue-mimicking material to manufacture stable phantoms for ultrasound and …

Oil gel-based phantom for evaluating quantitative accuracy of speed of sound measured in ultrasound computed tomography

A Suzuki, Y Tsubota, W Wu, K Yamanaka… - Ultrasound in Medicine …, 2019 - Elsevier
To evaluate the quantitative accuracy of the measured speed of sound in ultrasound
computed tomography for breast imaging, it is necessary to use a phantom with inclusions …

A stable phantom material for optical and acoustic imaging

L Hacker, AM Ivory, J Joseph, J Gröhl… - JoVE (Journal of …, 2023 - app.jove.com
Establishing tissue-mimicking biophotonic phantom materials that provide long-term stability
are imperative to enable the comparison of biomedical imaging devices across vendors and …

Technical Validation of Photoacoustic Imaging Systems Using Phantoms

L Hacker, J Joseph - Biomedical Photoacoustics: Technology and …, 2024 - Springer
Technical validation studies are paramount for objective performance evaluation and
calibration of novel imaging devices, aiding their development and effective translation into …

Biomimetic phantom with anatomical accuracy for evaluating brain volumetric measurements with magnetic resonance imaging

M Azimbagirad, FW Grillo, Y Hadadian… - Journal of Medical …, 2021 - spiedigitallibrary.org
Purpose: Brain image volumetric measurements (BVM) methods have been used to quantify
brain tissue volumes using magnetic resonance imaging (MRI) when investigating …

[PDF][PDF] Fabrication of a Stable, Biologically Relevant Phantom Material

L Hacker, AM Ivory, J Joseph, J Gröhl… - JoVE (Journal of …, 2023 - drive.google.com
Establishing tissue-mimicking biophotonic phantom materials that provide longterm stability
are imperative to enable the comparison of biomedical imaging devices across vendors and …

Ultrasound metrology and phantom materials for validation of photoacoustic thermometry

M Bakaric - 2022 - discovery.ucl.ac.uk
High intensity focused ultrasound is an emerging non-invasive cancer therapy during which
a focused ultrasound beam is used to destroy cancer cells within a confined volume of …

On the mechanics of visco-hyperelastic soft materials

K Upadhyay - 2020 - search.proquest.com
Soft materials such as elastomers, hydrogels, foams and biological tissues exhibit unique
mechanical properties that involve large elastic deformations, stress-strain nonlinearity, as …