The efficacy of XEN gel stent implantation in glaucoma: a systematic review and meta-analysis

X Yang, Y Zhao, Y Zhong, X Duan - BMC ophthalmology, 2022 - Springer
Background Xen is a device for minimally invasive glaucoma surgery, and is used to treat
POAG, pseudoexfoliative or pigmentary glaucoma, as well as refractory glaucoma. The …

Combined and stand‐alone XEN 45 gel stent implantation: 3‐year outcomes and success predictors

K Gillmann, GE Bravetti, HL Rao… - Acta …, 2021 - Wiley Online Library
Purpose To evaluate the 3‐year treatment outcomes of XEN 45 gel stent in open‐angle
glaucoma patients. Methods In this prospective, single‐centre interventional study …

Standalone Xen45 Gel Stent implantation versus combined Xen45-phacoemulsification in the treatment of open angle glaucoma—A systematic review and meta …

SY Lim, BK Betzler, LWL Yip, S Dorairaj… - Graefe's Archive for …, 2021 - Springer
Abstract Purpose The XEN45 Gel Stent is currently the only FDA-approved sub-conjunctival
minimally invasive glaucoma surgery (MIGS) procedure. It has been used worldwide either …

Preliminary results of preserflo microshunt versus preserflo microshunt and ologen implantation

I Vastardis, S Fili, G Perdikakis, K Kontopoulou… - Eye and Vision, 2021 - Springer
Purpose To report preliminary 6-month results on the use of the Preserflo Microshunt implant
with and without Ologen in 50 pseudophakic eyes with moderate to advanced primary open …

All consecutive ab externo SIBS Microshunt implantations with mitomycin C: one-year outcomes and risk factors for failure

MB Schlenker, JJ Armstrong, T De Francesco… - American Journal of …, 2023 - Elsevier
PURPOSE To present the effectiveness, risk factors for surgical failure, and adverse events
over 12 months in a consecutive diverse cohort of glaucoma patients who underwent solo or …

Outcomes and baseline predictors of failure in primary standalone Xen45 gel stent versus trabeculectomy for glaucoma

JCK Tan, Y Hashimoto, PH Gabrielle… - Ophthalmology …, 2024 - Elsevier
Purpose To compare safety, effectiveness, and baseline predictors of failure in standalone
primary Xen45 gel stent (Xen) versus trabeculectomy (Trab) in glaucoma. Design …

Choroidal detachment after XEN gel stent implantation

CA Cutolo, L Negri, S Olivari, F Cappelli… - Journal of …, 2021 - Wiley Online Library
Background. The purpose of this study is to estimate the incidence of choroidal detachment
(CD) after XEN gel stent implant surgery and to evaluate the associated factors. Methods …

[HTML][HTML] Bleb analysis using anterior segment optical coherence tomography and surgical predictors of XEN gel stent

Y Kim, SH Lim, S Rho - Translational vision science & …, 2022 - iovs.arvojournals.org
Purpose: To determine the early predictors of surgical success 6 months after XEN surgery
among clinical parameters, including anterior segment optical coherence tomography (AS …

Complications and post-operative interventions in XEN45 gel stent implantation in the treatment of open angle glaucoma—a systematic review and meta-analysis

BK Betzler, SY Lim, BA Lim, VCH Yip, BCH Ang - Eye, 2023 - nature.com
Abstract Background The XEN45 Gel Stent is a subconjunctival filtering device that has
demonstrated promising efficacy. This meta-analysis quantitatively evaluates reported …

Navigating hypotony challenges with XEN gel implantation

KA Elubous - Expert Review of Medical Devices, 2024 - Taylor & Francis
ABSTRACT Introduction The XEN Gel, a hydrophilic tube meticulously crafted to adhere to
the principles of the Hagen–Poiseuille law, is designed to facilitate efficient aqueous …