High-Resol Ution Spectroscopy of Stored Ions

DJ Wineland, WM Itano, RS Van Dyck Jr - Advances in atomic and …, 1983 - Elsevier
Publisher Summary This chapter reviews the high-resolution experiments that have
employed the stored ion technique. The main advantage of the stored ion techniques is that …

Quadrupole excitation of stored ion motion at the true cyclotron frequency

M König, G Bollen, HJ Kluge, T Otto… - International Journal of …, 1995 - Elsevier
The motion of an ion in a Penning trap has been investigated in the presence of an
azimuthal quadrupole radio frequency field and a damping force provided by buffer gas …

[图书][B] Charged particle traps: physics and techniques of charged particle field confinement

FG Major, VN Gheorghe, G Werth - 2005 - books.google.com
Over the last quarter of this century, revolutionary advances have been made both in kind
and in precision in the application of particle traps to the study of thephysics of charged …

Micromotion-induced limit to atom-ion sympathetic cooling in Paul traps

M Cetina, AT Grier, V Vuletić - Physical review letters, 2012 - APS
We present, and derive analytic expressions for, a fundamental limit to the sympathetic
cooling of ions in radio-frequency traps using cold atoms. The limit arises from the work …

ISOLTRAP: a tandem Penning trap system for accurate on-line mass determination of short-lived isotopes

G Bollen, S Becker, HJ Kluge, M König… - Nuclear Instruments and …, 1996 - Elsevier
The tandem Penning trap mass spectrometer ISOLTRAP has been set up at the on-line
mass separator ISOLDE at CERN/Geneva for accurate mass measurements of short-lived …

Collision measurements and excited-level lifetime measurements on ions stored in Paul, Penning and Kingdon ion traps

DA Church - Physics Reports, 1993 - Elsevier
Ion-collision and ion-excited level mean lifetime measurements carried out in Paul, Penning
and Kingdon ion traps are briefly reviewed. Low energy spin-dependent charged particle …

Cooling methods in ion traps

WM Itano, JC Bergquist, JJ Bollinger… - Physica Scripta, 1995 - iopscience.iop.org
In many experiments utilizing ion traps, the ions must be cooled in order to increase the
precision and accuracy of the measurements. Laser cooling is very effective when it can be …

[图书][B] Charged particle traps II

G Werth, VN Gheorghe, FG Major - 2009 - Springer
This second volume of the Charged Particle Traps deals with the rapidly expanding body of
research exploiting the electromagnetic confinement of ions, whose principles and …

Brownian motion of a parametric oscillator: A model for ion confinement in radio frequency traps

R Blatt, P Zoller, G Holzmüller, I Siemers - Zeitschrift für Physik D Atoms …, 1986 - Springer
The distribution function for Brownian motion of a parametric oscillator is calculated exactly
with the help of continued fraction expansions in the long time limit. We derive expressions …

Resonance excitation of ions stored in a quadrupole ion trap. Part 1. A simulation study

RE March, AW McMahon, FA Londry, RL Alfred… - International journal of …, 1989 - Elsevier
Preliminary findings are presented of a simulation study of resonance excitation of gaseous
ions stored within a quadrupole ion trap. The ion trap was operated in the common mode …