Current developments in corneal topography and tomography

P Kanclerz, R Khoramnia, X Wang - Diagnostics, 2021 - mdpi.com
Introduction: Accurate assessment of the corneal shape is important in cataract and
refractive surgery, both in screening of candidates as well as for analyzing postoperative …

Repeatability of automated measurements by a new anterior segment optical coherence tomographer and biometer and agreement with standard devices

D Schiano-Lomoriello, KJ Hoffer, I Abicca, G Savini - Scientific Reports, 2021 - nature.com
We assess repeatability of automatic measurements of a new anterior segment optical
coherence tomographer and biometer (ANTERION) and their agreement with those …

Repeatability of total Keratometry and standard Keratometry by the IOLMaster 700 and comparison to total corneal astigmatism by Scheimpflug imaging

G Savini, L Taroni, D Schiano-Lomoriello, KJ Hoffer - Eye, 2021 - nature.com
Objectives We aimed (1) to assess the repeatability of Total Keratometry (TK) and standard
keratometry (K) measurements, as provided by the IOLMaster 700 (Carl Zeiss Meditec), and …

[HTML][HTML] Consensus on the management of astigmatism in cataract surgery

MX Núñez, MA Henriquez, LJ Escaf… - Clinical …, 2019 - ncbi.nlm.nih.gov
This project was aimed at achieving consensus on the management of astigmatism during
cataract surgery by ophthalmologists from Latin America using modified Delphi technique …

Predictability of different calculators in the minimization of postoperative astigmatism after implantation of a toric intraocular lens

FJ Ribeiro, TB Ferreira, C Relha, C Esteves… - Clinical …, 2019 - Taylor & Francis
Purpose To assess the efficacy of five calculators for toric intraocular lenses (IOL). Methods
Retrospective comparative case series in cataract patients undergoing implantation of …

Repeatability of new optical biometer and agreement with 2 validated optical biometers, all based on SS-OCT

A Galzignato, E Lupardi, KJ Hoffer… - Journal of Cataract & …, 2023 - journals.lww.com
Purpose: To evaluate the repeatability of the measurements provided by a new optical
biometer (EyeStar 900) based on swept-source optical coherence tomography (SS-OCT) …

Comparison of anterior segment measurements obtained using a swept-source optical coherence tomography biometer and a Scheimpflug–Placido tomographer

W Lu, Y Li, G Savini, B Song, Q Hu, Q Wang… - Journal of Cataract & …, 2019 - Elsevier
Purpose To assess the repeatability and agreement of anterior segment measurements
between an optical biometer (IOLMaster 700) using swept-source optical coherence …

Repeatability of automatic measurements by an anterior segment swept-source OCT biometer in patients with Keratoconus

I Abicca, D Schiano-Lomoriello… - Journal of Refractive …, 2024 - journals.healio.com
Purpose: To evaluate the repeatability of automatic measurements of a new anterior
segment optical coherence tomographer (ANTERION; Heidelberg Engineering) and their …

Comparability and repeatability of different methods of corneal astigmatism assessment

TB Ferreira, FJ Ribeiro - Clinical Ophthalmology, 2017 - Taylor & Francis
Purpose To assess the comparability and repeatability of keratometric and astigmatism
values measured by four techniques: Orbscan IIz®(Bausch and Lomb), Lenstar LS …

A novel color-LED corneal topographer to assess astigmatism in pseudophakic eyes

TB Ferreira, FJ Ribeiro - Clinical Ophthalmology, 2016 - Taylor & Francis
Purpose To assess the accuracy of corneal astigmatism evaluation measured by four
techniques, Orbscan IIz®, Lenstar LS900®, Cassini®, and Total Cassini (anterior+ posterior …