Transformer design and optimization: a literature survey

EI Amoiralis, MA Tsili, AG Kladas - IEEE Transactions on power …, 2009 - ieeexplore.ieee.org
With the fast-paced changing technologies in the power industry, new references
addressing new technologies are coming to the market. Based on this fact, there is an urgent …

[图书][B] Transformer engineering

SV Kulkarni, SA Khaparde - 2004 - api.taylorfrancis.com
There have been considerable advancements in various aspects of transformer engineering
since the publication of the first edition in 2004. Improvements can be clearly seen in …

Derating of transformers under non‐linear load current and non‐sinusoidal voltage–an overview

J Faiz, M Ghazizadeh, H Oraee - IET Electric Power …, 2015 - Wiley Online Library
The increasing application of non‐linear loads in power system causes additional losses in
transformers resulting in premature damage. Manufactures and users of transformers realise …

A review of transformer losses

JC Olivares-Galván, PS Georgilakis… - Electric Power …, 2009 - Taylor & Francis
This article presents an extensive survey of current research on the transformer loss
problem, particularly from the view of practical engineering applications. It reveals that the …

[图书][B] Power and Distribution transformers: Practical design guide

KRM Nair - 2021 - taylorfrancis.com
This book is based on the author's 50+ years experience in the power and distribution
transformer industry. The first few chapters of the book provide a step-by-step procedures of …

Behavior of mold slag used for 20Mn23Al nonmagnetic steel during casting

X Yu, G Wen, P Tang, F Ma, H Wang - Journal of Iron and Steel Research …, 2011 - Springer
Because of the addition of significant quantities of aluminum and manganese, the great
challenge of casting 20Mn23Al nonmagnetic steel is to design a mold slag that is chemically …

Reduction of stray losses in flange–bolt regions of large power transformer tanks

JC Olivares-Galvan… - IEEE Transactions …, 2013 - ieeexplore.ieee.org
In large power transformers, the presence of stray currents in the structural elements near
the high current bushings can be considerable, and this leads to hot spots. This work …

Three-dimensional methodology for the overheating hazard assessment on transformer covers

XM Lopez-Fernandez… - IEEE Transactions …, 2012 - ieeexplore.ieee.org
In this paper, a 3-D methodology for the overheating hazard assessment on transformer
covers based on electromagnetic analytical formulation linked with thermal finite element …

[PDF][PDF] A Novel Approach for Evaluating Eddy Current Loss in Wind Turbine Generator Step-Up Transformers

BA Thango, JA Jordaan, AF Nnachi - Adv. Sci. Technol. Eng. Syst. J, 2021 - academia.edu
Wind energy is one of the principal renewable energy determinations by the South African
government, owing to affluent heavy winds in vast and remote coastal areas. In the design of …

Reduction of loss and local overheating in the tank of a current transformer

GB Kumbhar, SM Mahajan… - IEEE transactions on …, 2010 - ieeexplore.ieee.org
Transformer manufacturers often use low carbon steel for oil tanks to cut down production
costs. The low carbon steel tanks experience not only high eddy currents loss, but also suffer …