Voltage transient management for Alternating Current trains with vacuum circuit breakers

T Moore, F Schmid, P Tricoli - IET Electrical Systems in …, 2022 - Wiley Online Library
Alternating current power supplies and rolling stock with 25 kV (50 or 60 Hz) and 15 kV (16.7
Hz) traction systems do not have the characteristics and behaviour of a typical three‐phase …

[HTML][HTML] Measuring impedance frequency characteristics of magnetic rings with DC-bias current

K Kutorasiński, M Szewczyk, M Molas, J Pawłowski - ISA transactions, 2023 - Elsevier
This paper reports on a comprehensive study on a measurement method for the impedance
characteristics in the frequency domain of magnetic rings as a function of DC-bias current up …

Wind turbine transformers protection method against high-frequency transients

D Smugala, W Piasecki, M Ostrogorska… - IEEE transactions on …, 2015 - ieeexplore.ieee.org
A new wind turbine transformers protection method against high du/dt switching transients
taking place during a wind turbine operation is described. High-frequency transients …

Experimental research on suppressing VFTO in GIS by magnetic rings

Y Guan, G Yue, W Chen, Z Li… - IEEE Transactions on …, 2013 - ieeexplore.ieee.org
Very-fast transient overvoltage (VFTO) is a serious threat to the insulation of extra-high
voltage and ultra-high voltage power-system equipment and should be suppressed. A …

Controlled voltage breakdown in disconnector contact system for VFTO mitigation in gas-insulated switchgear (GIS)

M Szewczyk, M Kuniewski - IEEE Transactions on Power …, 2017 - ieeexplore.ieee.org
Several methods have been proposed and investigated so far on mitigation of very fast
transient overvoltages (VFTO) in gas-insulated switchgear (GIS). The state-of-the-art …

Determination of breakdown voltage characteristics of 1'100 kV disconnector for modeling of VFTO in gas-insulated switchgear

M Szewczyk, M Kuniewski, W Piasecki… - … on Power Delivery, 2015 - ieeexplore.ieee.org
This paper presents a method for determination of breakdown voltage characteristics (BDV)
of a gas-insulated switchgear (GIS) disconnector. The method is applicable for modeling …

Machine-Learned Models for Power Magnetic Material Characteristics

P Leszczynski, K Kutorasinski… - … on Power Electronics, 2024 - ieeexplore.ieee.org
We present a general framework for modeling power magnetic materials characteristics
using deep neural networks. Magnetic materials represented by multidimensional …

New concept for VFTO attenuation in GIS with modified disconnector contact system

M Szewczyk, W Piasecki, M Wroński… - IEEE Transactions on …, 2014 - ieeexplore.ieee.org
This paper investigates on a new concept for very-fast transient overvoltages (VFTOs)
attenuation in gas-insulated switchgear (GIS). The concept, first introduced by the authors in …

High-frequency model of magnetic rings for simulation of VFTO damping in gas-insulated switchgear with full-scale validation

M Szewczyk, J Pawłowski… - … on power delivery, 2015 - ieeexplore.ieee.org
Nanocrystalline magnetic rings have been experimentally proven for effective damping of
very fast transient overvoltages (VFTOs) in gas-insulated switchgear (GIS). The application …

Analysis of influential factors in determining Very Fast Transient Overvoltages of GIS substations

M Babaei, M Babaei, G Nourirad - 2014 IEEE 8th International …, 2014 - ieeexplore.ieee.org
High voltage Gas Insulated Substation (GIS) is threatened by Very Fast Transient
Overvoltage (VFTO) which is high amplitude and high frequency transient within the range …