VSC input-admittance modeling and analysis above the Nyquist frequency for passivity-based stability assessment

L Harnefors, R Finger, X Wang, H Bai… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
The interconnection stability of a grid-connected voltage-source converter can be assessed
via the dissipative properties of its input admittance. In this paper, the modeling of the current …

Passivity-based design of passive damping for LCL-type grid-connected inverters to achieve full-frequency passive output admittance

G Ma, C Xie, C Li, J Zou… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
The frequency-domain passivity theory suggests that incorporating passive output
admittance in grid-connected inverters (GCIs) can effectively mitigate system instability …

Sideband harmonic instability of paralleled inverters with asynchronous carriers

D Yang, X Wang, F Blaabjerg - IEEE Transactions on Power …, 2017 - ieeexplore.ieee.org
Paralleled inverters with asynchronous carriers are increasingly emerging into renewable
power plants and other power-electronic-based power systems. The sideband harmonics …

Passivity based damping design for grid-connected converter with improved stability

H Liu, L Li, Y Liu, D Xu, Q Gao - IEEE Access, 2019 - ieeexplore.ieee.org
The impedance interactions between weak grid and LCL-filtered converter can bring severe
harmonic resonance. Recently, frequency domain passivity theory has been applied to …

Passivity-Based Design of External Passive Damper for LCL-Type Grid-Connected Inverter

G Ma, C Xie, C Li, C Peng, J Zou - IEEE Transactions on Power …, 2024 - ieeexplore.ieee.org
To enhance the interactive stability between an LCL-type grid-connected inverter (GCI) and
the grid, a passive damper (PD) is necessary for passivizing the output admittance of the …

Design of passive power filters for battery energy storage system in grid connected and islanded modes

N Mdini, S Skander-Mustapha, I Slama-Belkhodja - SN Applied Sciences, 2020 - Springer
This study presents an improved method to design passive power filters for a battery energy
storage system operating in grid connected and islanded modes. The studied system …

A virtual RLC active damping method for LCL-type grid-connected inverters

Y Geng, Y Qi, P Zheng, F Guo, X Gao - Journal of Power Electronics, 2018 - koreascience.kr
Proportional capacitor-current-feedback active damping (AD) is a common damping method
for the resonance of LCL-type grid-connected inverters. Proportional capacitor-current …

Pareto-Optimal Design of Passive Damping for Megawatt Grid-Connected Inverters

G Ma, C Xie, C Li, W Wang, J Zou - 2023 IEEE 2nd International …, 2023 - ieeexplore.ieee.org
Replacing the capacitor current with the derivative of its voltage in the active damping (AD)
loop of a grid-connected inverter (GCI) can save cost and gain popularity. However, the first …

Passivity-based parameter design of passive power filter for the grid-current-controlled VSC

J Zhao, C Xie, K Li - 2020 IEEE Energy Conversion Congress …, 2020 - ieeexplore.ieee.org
The interaction between the voltage source converters (VSCs) and the grid would bring
about high-frequency resonance problem. For the grid-connected VSC, the non-passivity of …

Comparative Evaluation of Several Types of Passive Damping Branches for Grid-Connected Inverters under Passivity

G Ma, C Xie, C Li, Y Han, W Wang… - 2024 IEEE 10th …, 2024 - ieeexplore.ieee.org
The passive damping (PD) branches based on passive design can provide sufficient
passivity compensation to the output admittance of the grid-connected inverter (GCI) at the …