Neurochemical dynamics of acute orofacial pain in the human trigeminal brainstem nuclear complex

NMP De Matos, A Hock, M Wyss, DA Ettlin, M Brügger - Neuroimage, 2017 - Elsevier
The trigeminal brainstem sensory nuclear complex is the first central relay structure
mediating orofacial somatosensory and nociceptive perception. Animal studies suggest a …

Simultaneous functional MRI acquisition of distributed brain regions with high temporal resolution using a 2D‐selective radiofrequency excitation

J Finsterbusch - Magnetic resonance in medicine, 2015 - Wiley Online Library
Purpose To perform simultaneous functional MRI of multiple, distributed brain regions at
high temporal resolution using a 2D‐selective radiofrequency (2DRF) excitation. Methods A …

A new sequence for shaped voxel spectroscopy in the human brain using 2D spatially selective excitation and parallel transmission

P Waxmann, R Mekle, F Schubert, R Brühl… - NMR in …, 2016 - Wiley Online Library
Spatially selective excitation in two dimensions (2D‐SSE) utilizing parallel transmission was
applied as a means to acquire signal from voxels adapted to the anatomy of interest for in …

Parallel transmit optimized 3D composite adiabatic spectral‐spatial pulse for spectroscopy

X He, EJ Auerbach, M Garwood… - Magnetic resonance …, 2021 - Wiley Online Library
Purpose To develop a 3D composite adiabatic spectral‐spatial pulse for refocusing in spin‐
echo spectroscopy acquisitions and to compare its performance against standard …

Reproducibility of neurochemical profile quantification in pregenual cingulate, anterior midcingulate, and bilateral posterior insular subdivisions measured at 3 Tesla

NMP De Matos, L Meier, M Wyss, D Meier… - Frontiers in human …, 2016 - frontiersin.org
The current report assessed measurement reproducibility of proton magnetic resonance
spectroscopy at 3 Tesla in the left and right posterior insular, pregenual anterior cingulate …

Signal scaling improves the signal‐to‐noise ratio of measurements with segmented 2D‐selective radiofrequency excitations

J Finsterbusch, MG Busch… - Magnetic resonance in …, 2013 - Wiley Online Library
Purpose Segmented 2D‐selective radiofrequency excitations can be used to acquire
irregularly shaped target regions, eg, in single‐voxel MR spectroscopy, without involving …

Sculpting 3D spatial selectivity with pairs of 2D pulses: A comparison of methods

G Farkash, JN Dumez, L Frydman - Journal of Magnetic Resonance, 2016 - Elsevier
Enhancing the specificity of the spins' excitation can improve the capabilities of magnetic
resonance. Exciting voxels with tailored 3D shapes reduces partial volume effects and …

Robust methods and sequences for achieving n-dimensional localization In-Vivo with magnetic resonance spectroscopy and imaging

G Farkash - 2018 - search.proquest.com
This dissertation summarizes my Ph. D. research on advanced localization techniques for
magnetic resonance imaging (MRI) and spectroscopy (MRS). The goal of this work was to …

[PDF][PDF] SHAVE-eine Sequenz für die Magnetresonanzspektroskopie mit räumlich-selektiver Anregung zweidimensional geformter Voxel

P Waxmann - 2018 - opendata.uni-halle.de
This work fits into a series of studies on the use of spatially selective excitation (SSE) to
produce arbitrarily shaped acquisition volumes in MR spectroscopy. Acquisition volumes …