From lead management to implanted patient management: systematic review and meta-analysis of the last 15 years of experience in lead extraction

I Diemberger, A Mazzotti, M Biffi… - Expert review of …, 2013 - Taylor & Francis
Percutaneous lead extraction is considered a safe and effective procedure, although
published results derive primarily from cohort studies. The authors performed a systematic …

From lead management to implanted patient management: indications to lead extraction in pacemaker and cardioverter–defibrillator systems

I Diemberger, M Biffi, C Martignani… - Expert Review of …, 2011 - Taylor & Francis
Based on the published results primarily from cohort studies, percutaneous lead extraction is
now considered a safe procedure and indications for its use have broadened from device …

Multicenter experience with transvenous lead extraction of active fixation coronary sinus leads

M Maytin, RG Carrillo, P Baltodano… - Pacing and clinical …, 2012 - Wiley Online Library
Background/Objective: Active fixation coronary sinus (CS) leads limit dislodgement and
represent an attractive option to the implanter. Although extraction of passive fixation CS …

Pacemaker and defibrillator lead extraction: predictors of mortality during follow‐up

S Hamid, A Arujuna, M Ginks… - Pacing and clinical …, 2010 - Wiley Online Library
Background: Extraction of cardiac implantable electric devices is an accepted procedure
when systems become infected or malfunction. However, there is an associated morbidity …

Large, single‐center experience in transvenous coronary sinus lead extraction: procedural outcomes and predictors for mechanical dilatation

A Di Cori, MG Bongiorni, G Zucchelli… - Pacing and clinical …, 2012 - Wiley Online Library
Background: The aim of this study was to evaluate procedural outcomes of coronary sinus
(CS) lead extraction, focusing on predictors and need for mechanical dilatation (MD) in the …

Percutaneous lead and system extraction in patients with cardiac resynchronization therapy (CRT) devices and coronary sinus leads

SE Williams, A Arujuna, J Whitaker… - Pacing and clinical …, 2011 - Wiley Online Library
Background: Cardiac resynchronization therapy (CRT) device and coronary sinus (CS) lead
extraction is required due to the occurrence of system infection, malfunction, or upgrade …

Usefulness of mechanical transvenous dilation and location of areas of adherence in patients undergoing coronary sinus lead extraction

MG Bongiorni, G Zucchelli, E Soldati, G Arena… - Europace, 2007 - academic.oup.com
Aims Few data have been currently reported on the outcome of coronary sinus (CS) lead
removal, particularly using mechanical dilation (MD). We aimed to evaluate feasibility …

Effectiveness of excimer laser‐assisted pacing and ICD lead extraction in children and young adults

JP Moak, V Freedenberg, C Ramwell… - Pacing and clinical …, 2006 - Wiley Online Library
Background: High capture thresholds, decreased electrical sensing, and lead fractures
continue to be a problem in children undergoing transvenous pacing. The clinician must …

First experience with a new active fixation coronary sinus lead

H Nägele, M Azizi, S Hashagen, MA Castel… - Europace, 2007 - academic.oup.com
Aims Coronary sinus (CS) lead implantation is a technically challenging procedure owing to
variable vein anatomies and a high dislocation rate. Therefore, CS lead technology has …

Extraction of chronic pacemaker and defibrillator leads from the coronary sinus: laser infrequently used but required

S Hamid, A Arujna, S Khan, A Ladwiniec, M McPhail… - Europace, 2009 - academic.oup.com
Aims Cardiac resynchronization therapy is an accepted treatment for heart failure but it may
be necessary to explant these systems along with their leads. The evidence base for …